9.10 Access to the pumps/manifolds

Important!
Do not fit the circulation pump in place of the drain pump
and vice versa.

9.10.1 Drain pump (standard version)

To access the drain pump, it is not necessary to remove the rear
cabinet shell. The pump can be accessed from the base.
a. Detach the clamps which secure the filter body to the base
and raise slightly (66)
b. Remove the drain pump
c. Detach the drain hose
d. Detach the wiring connectors
When re-assembling, ensure that the OR seal is fitted to the
pump. To facilitate insertion, lubricate with vaseline or silicone oil.
Check that the pump is correctly housed in its seat in the filter
body.

9.10.2 Drain pump - models with P66 (32cm) cabinet

Access to the pump is from the base of the appliance:
a. Slightly raise the clamp and remove the pump from the base
(67)
b. Detach the drain hose and the hose between the pump and
the tub
c. Detach the wiring connectors

9.10.3 Drain pump - models with RIM and P63 soft BD cabinets

Access to the pump is from the base of the appliance:
a. Remove the cover
b. Detach the connectors
c. Press down the anchor tab (68c)
d. Turn the pump counter-clockwise (68d)
e. Remove the pump (68e)
When re-assembling:
• Insert the pump fully into its seat in the filter body before
rotating it.
• Check that the anchor tab is undamaged. If so, use a
3.5x19 mm screw to secure the pump (69)