Bathside Control Systems - Aquatic iNfiNity serIes Owner's Manual & Installation Manual

Infinity series
Hide thumbs Also See for iNfiNity serIes:
Table of Contents

Advertisement

iNFiNiTy SEriES WhirLPOOLS
NOTE: dO NOT STArT PuMP uNTiL ALL jETS ArE SuBMErgEd. WATEr LEVEL ShOuLd
BE 2" ABOVE highEST jET.

BAThSidE CONTrOL SySTEMS:

iNFiNiTy ON/OFF WiTh hEATEr CONTrOL (SEE diAgrAM 6A):
1. to turn Pump On: Pressing the On/Off
off. A built-in timer will turn the pump and heater off after 20 minutes.
2. To Change Temperature: The heater
shows the actual set point. By pressing up or down, the set point can be changed. Keeping the buttons pressed
changes the setting continuously. the temperature can vary from 90° to 104° f.
Note: The set point light (sp) is "On" when the display shows the set point and "Off" when it shows the actual water
temperature. The heater's LED will blink when the system calls for heat and will stay on when the heater is "On".
The control turns the heater "On" when the temperature reaches the set point —1° F and keeps it on until it reaches
the set point +1° f.
3. for infinity 1: to turn Continuous Waterfall On: Pressing and holding down the chromatherapy
seconds will turn the continuous waterfall on. Depressing the chromatherapy button for 2 seconds with the continuous
waterfall on will turn off the waterfall. However, the light output will automatically turn off after 2 hours; the continuous
waterfall will automatically turn off after 20 minutes. Note: the
continuous waterfall is only featured on the infinity 1.
Other Features:
• When power is on, the control displays "000" for five seconds
and then blanks itself.
• When the pump is shut off, the display shows the water
temperature for a period of 15 minutes.
• The High-Limit circuit will shut the heater off if the temperature
of the water at the High-Limit sensor reaches 119° f. Should
this occur, the display will show "• • • " but the pump will still
be allowed to work. Only the heater will be shut off. in order for
the heater to be reactivated the user must reset circuit breaker
when the temperature has fallen below 119° f.
• When the pump is on, the display will normally show the current
water temperature reading and the remaining minutes on the timer. this will toggle every 5 seconds.
aquatic Industries, Inc.
OPErATiON of
button will turn the pump on. Pressing a second time will turn the pump
and
buttons are used to set water temperature. When pressed, the display
heater On indicator
Set Point indicator
6A
button for 2
15

Hide quick links:

Advertisement

Table of Contents
loading