Comtech EF Data CDM-800 Installation And Operation Manual

Advanced vsat series gateway router
Hide thumbs Also See for CDM-800:
Table of Contents

Advertisement

Quick Links

CDM-800
Advanced VSAT Series Gateway Router
Installation and Operation Manual
For Firmware Version 1.3.2 or Higher
IMPORTANT NOTE: The information contained in this document supersedes all previously published
information regarding this product. Product specifications are subject to change without prior notice.
Part Number
MN-CDM800 Revision 1

Advertisement

Table of Contents
loading

Summary of Contents for Comtech EF Data CDM-800

  • Page 1 CDM-800 Advanced VSAT Series Gateway Router Installation and Operation Manual For Firmware Version 1.3.2 or Higher IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specifications are subject to change without prior notice.
  • Page 3 Installation and Operation Manual For Firmware Version 1.3.2 or Higher Part Number MN-CDM800 Revision 1 Copyright © 2012 Comtech EF Data. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161...
  • Page 4                                             This page is intentionally blank.
  • Page 5: Table Of Contents

    Electrical Installation  .......................... xi  Operating Environment ........................... xi  European Union Radio Equipment and Telecommunications Terminal Equipment (R&TTE)  Directive (1999/5/EC) and EN 301 489‐1 .................... xi  European Union Electromagnetic Compatibility (EMC) Directive (2004/108/EC) ...... xii  European Union Low Voltage Directive (LVD) (2006/95/EC)  .............. xii  European Union RoHS Directive (2002/95/EC)  ...................xiii  European Union Telecommunications Terminal Equipment Directive (91/263/EEC)  ......xiii  CE Mark ...............................xiii  Warranty Policy ..........................  x iv  Limitations of Warranty ..........................  x iv  Exclusive Remedies .......................... xv  Getting Help ............................  x vi  Contacting Comtech EF Data ........................  x vi  Returning a Product for Upgrade or Repair  ...................  x vii  CHAPTER 1.  INTRODUCTION ..................... 1–1  1.1  Overview .......................... 1–1 ...
  • Page 6 CDM-800 Gateway Router Revision 1 Table of Contents MN-CDM800 1.2  CDM‐800 Functional Description  ................... 1–2  1.3  CDM‐800 Features ........................ 1–4  1.3.1  Physical Description  ........................ 1–4  1.3.2  Dimensional Envelope ...................... 1–4  1.3.3  CDM‐800 Physical Features ...................... 1–5  1.3.3.1  Front Panel  ........................ 1–5  1.3.3.2  Rear Panel ......................... 1–6  1.3.3.2.1  Rear Panel Standard Features.................. 1–6  1.3.3.2.2  Rear Panel Optional Features .................. 1–7  1.4  CDM‐800 Specifications ...................... 1–8  1.4.1  Product Feature Specifications  .................... 1–8  1.4.2  Standard Assemblies......................... 1–9 ...
  • Page 7 CDM-800 Gateway Router Revision 1 Table of Contents MN-CDM800 3.2.4.3  ‘REDUNDANCY’ Connector  .................... 3–8  3.2.4.4  ‘CONSOLE’ Interface Connector  .................. 3–9  3.2.5  ‘(EXTERNAL) REFERENCE IN/OUT’ Connector  ................ 3–9  3.3  CDM‐800 Ground and Power Connections ................ 3–10  3.3.1  Chassis Ground Interface  ...................... 3–10  3.3.2  115V/230V Alternating Current (AC) Power Interface (Standard) ......... 3–11  3.3.2.1  AC Operation – Applying Power  .................. 3–11  3.3.2.2  AC Operation – Replacing Fuses .................. 3–12  3.3.3  48V Direct Current (DC) Power Interface (Optional)  .............. 3–13  3.3.3.1  DC Operation  – Applying Power.................. 3–13 ...
  • Page 8 CDM-800 Gateway Router Revision 1 Table of Contents MN-CDM800 5.4.4.2  Admin (Administration) Pages .................. 5–10  5.4.4.2.1  Admin | Access ...................... 5–10  5.4.4.2.2  Admin | SNMP ...................... 5–11  5.4.4.2.3  Admin | FAST ...................... 5–12  5.4.4.2.4  Admin | Firmware  ..................... 5–14  5.4.4.2.5  Admin | Auto Logout .................... 5–15  5.4.4.2.6  Admin | VMS  ...................... 5–16  5.4.4.3  Configuration Pages ...................... 5–18  5.4.4.3.1  Configuration | Interface .................. 5–18  5.4.4.3.1.1  Configuration | Interface | FE Mgt .............. 5–18  5.4.4.3.1.2  Configuration | Interface | GE‐1 or GE‐2  ............ 5–19  5.4.4.3.2  Configuration | Mod (Modulator) ................ 5–20  5.4.4.3.3  Configuration | ARP .................... 5–22 ...
  • Page 9 CDM-800 Gateway Router Revision 1 Table of Contents MN-CDM800 A.2  FAST Activation via the Web Server Interface ............... A–2  APPENDIX B. FEC (FORWARD ERROR CORRECTION) ............. B–1  B.1  Introduction ......................... B–1  B.2  DVB‐S2: LDPC and BCH  ...................... B–1  B.2.1  Range of Data Rates........................  B –1  B.2.2  BER, QEF, Eb/No, Es/No Spectral Efficiency, and Occupied Bandwidth ..........  B –1  B.3  CDM‐800 Error Performance Characteristics ................. B–2  TABLES Table 3‐1.  REDUNDANCY Connector Pinout .................... 3–8  Table 3‐2.  CONSOLE Connector Pinout  .................... 3–9 ...
  • Page 10 CDM-800 Gateway Router Revision 1 Table of Contents MN-CDM800 Figure 5‐6. Admin | Firmware page  ...................... 5–14  Figure 5‐7. Admin | Auto Logout page .................... 5–15  Figure 5‐8. Admin | VMS page  ........................ 5–16  Figure 5‐9. Configuration | Interface | FE Mgt Page ................ 5–18  Figure 5‐10. Configuration | Interface | GE‐1 or GE‐2 Page  .............. 5–19  Figure 5‐11. Configuration | Mod page .................... 5–20  Figure 5‐12. Configuration | ARP page .................... 5–22  Figure 5‐13. Configuration | Routing | Routes page ................ 5–23  Figure 5‐14. Configuration | Compression page  .................. 5–25  Figure 5‐15. Configuration | WAN | QoS page .................. 5–26  Figure 5‐16. Configuration | WAN | QoS page (continued) .............. 5–27  Figure 5‐17. Status | Statistics | Traffic page.................. 5–34  Figure 5‐18. Status | Statistics | Router page  .................. 5–36  Figure 5‐19. Status | Statistics | Compression page  ................ 5–37  Figure 5‐20. Status | Statistics | QoS page ..................... 5–38  Figure 5‐21. Status | Statistics | VCM page .................... 5–41  Figure 5‐22. Status | Monitor page ...................... 5–43  Figure 5‐23. Utility | Utility page ...................... 5–44  Figure 5‐24. Utility | Reboot page ...................... 5–47 ...
  • Page 11: Preface

    • Comtech EF Data ODM‐840 Outdoor Remote Router /ODMR‐840 Reduced Form Factor Outdoor  Remote Router Installation and Operation Manual    • Comtech EF Data CDD‐880 Multi Receiver Router Installation and Operation Manual    Conventions and References Patents and Trademarks See all of Comtech EF Data's Patents and Patents Pending at http://patents.comtechefdata.com. Comtech EF Data acknowledges that all trademarks are the property of the trademark owners.  ...
  • Page 12: Warnings, Cautions, And Notes

    CDM-800 Gateway Router Revision 1 Preface MN-CDM800 Warnings, Cautions, and Notes A WARNING gives information about a possible hazard that MAY CAUSE DEATH or SERIOUS INJURY. A CAUTION gives information about a possible hazard that MAY CAUSE INJURY or PROPERTY DAMAGE.
  • Page 13: Safety And Compliance

    CDM-800 Gateway Router Revision 1 Preface MN-CDM800     The user should carefully review the following information:  Safety and Compliance Electrical Safety and Compliance The unit complies with the EN 60950 Safety of Information Technology Equipment (Including  Electrical Business Machines) safety standard.    IF THE UNIT IS OPERATED IN A VEHICLE OR MOVABLE INSTALLATION, MAKE SURE    THE UNIT IS STABLE. OTHERWISE, EN 60950 SAFETY IS NOT GUARANTEED.  Electrical Installation CONNECT THE UNIT TO A POWER SYSTEM THAT HAS SEPARATE GROUND, LINE AND  NEUTRAL  CONDUCTORS.  DO  NOT  CONNECT  THE  UNIT  WITHOUT  A  DIRECT ...
  • Page 14: European Union Electromagnetic Compatibility (Emc) Directive (2004/108/Ec)

    CDM-800 Gateway Router Revision 1 Preface MN-CDM800 Common  technical  requirements),  and  the  Declarations  of  Conformity  for  the  applicable  directives, standards, and practices that follow:  European Union Electromagnetic Compatibility (EMC) Directive (2004/108/EC) • Emissions:  EN  55022  Class  B  –  Limits  and  Methods  of  Measurement  of  Radio ...
  • Page 15: European Union Rohs Directive (2002/95/Ec)

    CDM-800 Gateway Router Revision 1 Preface MN-CDM800   For additional symbols, refer to Warnings, Cautions and Notes listed earlier in this  Preface.  European Union RoHS Directive (2002/95/EC) This unit satisfies (with exemptions) the requirements specified in the European Union Directive  on  the  Restriction  of  Hazardous  Substances  in  Electrical  and  Electronic  Equipment  (EU  RoHS,  Directive 2002/95/EC).  European Union Telecommunications Terminal Equipment Directive (91/263/EEC) In  accordance  with  the  European  Union  Telecommunications  Terminal  Equipment  Directive ...
  • Page 16: Warranty Policy

    Comtech  EF  Data  will  return  the  equipment  by  the  same  method  (i.e.,  Air,  Express,  Surface) as the equipment was sent to Comtech EF Data.    All equipment returned for warranty repair must have a valid RMA number issued prior  to  return  and  be  marked  clearly  on  the  return  packaging.    Comtech  EF  Data  strongly  recommends all equipment be returned in its original packaging.      Comtech EF Data Corporation’s obligations under this warranty are limited to repair or  replacement  of  failed  parts,  and  the  return  shipment  to  the  buyer  of  the  repaired  or ...
  • Page 17: Exclusive Remedies

    Exclusive Remedies Comtech  EF  Data  Corporation’s  warranty,  as  stated  is  in  lieu  of  all  other  warranties,  expressed,  implied,  or  statutory,  including  those  of  merchantability  and  fitness  for  a  particular purpose.  The buyer shall pass on to any purchaser, lessee, or other user of  Comtech  EF  Data  Corporation’s  products,  the  aforementioned  warranty,  and  shall ...
  • Page 18: Getting Help

    CDM-800 Gateway Router Revision 1 Preface MN-CDM800 Getting Help Review the Warranty Policy before contacting Comtech EF Data Technical Support or Customer Service.   Contacting Comtech EF Data Contact Comtech EF Data for:    • Technical Support – Product support or training.     • Customer Service – Information on returning an in‐warranty or out‐of‐warranty product for  upgrade  or  repair.  Be  prepared  to  provide  the  product  model  number  and  its  serial ...
  • Page 19: Returning A Product For Upgrade Or Repair

    CDM-800 Gateway Router Revision 1 Preface MN-CDM800 Returning a Product for Upgrade or Repair Step  Task  Go to the Comtech EF Data Service page (http://www.comtechefdata.com/  1  service.asp) and read the Return Material Authorization section in its entirety.   2  Request a Return Material Authorization Number:     • On the Comtech EF Data Service page: Select the Return Material  Authorization hyperlink.    • On the Comtech EF Data Support page:  (http://www.comtechefdata.com/support.asp): Click [Send RMA Request]  (http://www.comtechefdata.com/rmaform.asp);    • Fill out the RMA form completely;    • Click [Send Email].    • Alternately:    ...
  • Page 20 CDM-800 Gateway Router Revision 1 Preface MN-CDM800 Notes:                                                    xviii...
  • Page 21: Chapter 1. Introduction

    Chapter 1. INTRODUCTION Overview   Figure 1-1. CDM-800 Gateway Router   The CDM‐800 Gateway Router (Figure 1‐1) is a point‐to‐multipoint router. It serves as the “hub” or  local site equipment component of Comtech EF Data’s Advanced VSAT Series group of products.     Comtech’s Advanced VSAT Series group of products (Figure 1‐2) are designed to support latency‐ sensitive applications such as cellular backhaul over satellite, Universal Service Obligation (USO)  networks,  corporate  networks,  Internet  Service  Providers,  and  other  similar  hub‐and‐spoke  network  environments  that  require  high‐performance,  high‐quality  E1  and  IP  transport  with  “always‐on” availability.     ...
  • Page 22: Functional Description

    CDM-800 Gateway Router Revision 1 Introduction MN-CDM800 The  CDM‐800  features  two  10/100/1000  Gigabit  Ethernet  (GigE)  interfaces,  one  10/100  Fast  Ethernet  (FE)  interface,  and  provides  WAN  bandwidth  optimization.  The  unit  also  features  DVB‐S2 FEC coding.      • Sect. 1.3 CDM‐800 Features  • Sect. 1.4 CDM‐800 Specifications  CDM-800 Functional Description The CDM‐800 Gateway Router: ...
  • Page 23 CDM-800 Gateway Router Revision 1 Introduction MN-CDM800   • Sect. 5.3 (ETHERNET‐BASED PRODUCT MANAGEMENT) SNMP (MIB II and  Private MIB)  •   Sect. 5.4 (ETHERNET‐BASED PRODUCT MANAGEMENT) Web Server (HTTP)  Interface  • Chapter 6. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT    Field update of the operating system firmware is possible through file upload via satellite or the  Ethernet port.       Chapter 4. UPDATING FIRMWARE     Field activation of software‐based options is possible through Comtech’s FAST (Fully Accessible  System Topology) Feature upgrade process.      • Sect. 5.4.4.2.3 (CDM‐800 Web Server Interface)  Admin | FAST Page  • Appendix A. FAST        1–3...
  • Page 24: Features

    1.3.1 Physical Description The CDM‐800 Gateway  Router is constructed as a  1RU‐high rack‐mounting chassis. Handles at  the  front  facilitate  removal  from  and  placement  into  a  rack.  The  unit  can  be  free‐standing  if  desired.    •   Sect. 1.4 CDM‐800 Product Specifications  • Sect. 2.1 Installation into a Rack Enclosure  1.3.2 Dimensional Envelope     Figure 1-3. CDM-800 Dimensional Envelope 1–4...
  • Page 25: Physical Features

    CDM-800 Gateway Router Revision 1 Introduction MN-CDM800 1.3.3 CDM-800 Physical Features 1.3.3.1 Front Panel   Figure 1-4. CDM-800 – Front Panel View The front panel of the CDM‐800 (Figure 1‐4) features eight Light‐Emitting Diode (LED) indicators.  These LEDs convey operational states as follows:    LED  Condition  Green  No Unit Faults or Alarms.  UNIT STATUS    Amber  No Unit Faults, but an Alarm exists.  Red  A Unit Fault exists (Example: PSU fault).  There is a Stored Event in the log, which can be viewed from the Web  Amber  Server Interface or retrieved via the SNMP interface.  STORED EVENT  Off  There are no Stored Events. ...
  • Page 26: Rear Panel

                      (Top) Standard AC Unit   (Bottom) Optional 48V DC Unit Figure 1-5. CDM-800 – Rear Panel View 1.3.3.2.1 Rear Panel Standard Features The unit provides the following standard interfaces:    Data Interfaces:    • (2X) 10/100/1000 BaseT Gigabit Ethernet RJ‐45 Interfaces (GE1, GE2 ports) for Ethernet  traffic.    •...
  • Page 27: Rear Panel Optional Features

    Rear Panel Optional Features The unit provides the following Data Interface for optional hardware operation:    • (1X)  DB‐9M  EIA‐232  connector  labeled  “REDUNDANCY”  for  interoperability  with  a  separately  purchased  Comtech  EF  Data  CRS‐170A  1:1  Redundancy  Switch  for  L‐Band  operation, or the CRS‐180 1:1 Redundancy Switch for 70/140 MHz operation.    M:N  device  redundancy  support  is  available  with  the  separately  purchased  Vipersat  Management System (VMS). ...
  • Page 28: Specifications

    CDM-800 Gateway Router Revision 1 Introduction MN-CDM800 CDM-800 Specifications 1.4.1 Product Feature Specifications Specification Description 8 Light-emitting Diodes (LEDs): • UNIT STATUS (Green/Orange/Red) • TRANSMITTER ON (Green) Front Panel • STORED EVENT (Amber) • Tx TRAFFIC (Green) • ONLINE (Green) •...
  • Page 29: Standard Assemblies

    CDM-800 Modulator Board Assembly CDM-800 chassis 1.4.3 Optional Assemblies CEFD Item No. Description Where Installed PL-0000900 CDM-800 Base Chassis Assembly (48V DC) – KT/6228-2 Rear-Mounting Support Bracket (4”) Sides of CDM-800 chassis / rear of user-supplied mounting rack KT/6228-3 Rear-Mounting Support Bracket (10”) 1.4.4...
  • Page 30 CDM-800 Gateway Router Revision 1 Introduction MN-CDM800 Notes:                                                    1–10...
  • Page 31: Chapter 2. Installation

    Chapter 2. INSTALLATION Unpacking and Inspection                                                     Figure 2-1. Unpacking and Inspecting the Shipment   The ...
  • Page 32: Installation Into A Rack Enclosure

    Air  temperature  inside  the  rack  enclosure  should  never  exceed  50 C  ° (122 F).    For  information  about  custom  rack  enclosures,  contact  Comtech  EF  Data  Customer Support during normal business hours or visit Comtech EF Data’s Web  site (www.comtechefdata.com/support.asp).    •   The  CDM‐800  CANNOT  have  rack  slides  mounted  to  the  sides  of  the  chassis. ...
  • Page 33: Figure 2-2. Installation Into A Rack Enclosure

    CDM-800 Gateway Router Revision 1 Installation MN-CDM800                                                                 Figure 2-2. Installation into a Rack Enclosure  ...
  • Page 34: Installing The Optional Rear-Mounting Support Brackets Kit

    CDM-800 Gateway Router Revision 1 Installation MN-CDM800 2.2.1 Installing the Optional Rear-Mounting Support Brackets Kit Tools needed to install the KT/6228‐2 (4”) or KT/6228‐3 (10”) Bracket Kit:    • A medium Phillips™ screwdriver    • A 5/32‐inch SAE Allen™ Wrench    • An adjustable Crescent™ wrench.    To install the CEFD Chassis‐Style kit:    Step  Task  Use  the  #10  flat  washers,  #10  split  washers,  and  #10  hex  nuts  to  secure  the  #10 ...
  • Page 35: Figure 2-3. Installation Of Optional Rear-Mounting Support Brackets Kit

    CDM-800 Gateway Router Revision 1 Installation MN-CDM800                                   Detail  Description      1  Back of Unit    2  Rack Enclosure Threaded Rear Mounting Rail (typical)      Kit / Quantity  Item  Part Number  Description  KT/6228‐2 ...
  • Page 36 CDM-800 Gateway Router Revision 1 Installation MN-CDM800 Notes:                                                    2–6...
  • Page 37: Chapter 3. Rear Panel Connections

    The  CDM‐800  Gateway  Router  uses  a  number  of  different  cables.  Each  cable  type  is  typically  dedicated to a specific mode of operation.     Not all of these operational interface types may be available with this product. 3.1.1 Coaxial Cable Connections Connector Type  Coupling Type  Plug  Jack      Bayonet  (Type ‘BNC’ shown)      Threaded  (Type ‘N’ shown)  Figure 3‐1. Coaxial Connector Examples  The types of coaxial cables used by Comtech EF Data are ‘BNC’, ‘TNC’, ‘N’, ‘F’, and ‘SMA’. Coaxial  cables (plugs) and  their mating  connectors (jacks/sockets) are available in  two coupling styles:  Bayonet or Threaded.  3–1...
  • Page 38: Type 'Bnc

    CDM-800 Gateway Router Revision 1 Rear Panel Connections MN-CDM800   • Bayonet Coupling Style: The jack has a pair of guide posts that accommodate the plug’s  lockdown slots. This lockdown design provides secure assembly without over‐tightening  the connection.    • Threaded  Coupling  Style:  The  jack  features  external  threads.  The  plug  shell  features  internal threads, and has either a knurled outer surface to permit hand‐tightening of the  connection, or hex flats to accommodate torqued installation.    Connection Instructions:    • Bayonet Coupling Connections: Use the plug slots to guide, then slide the plug onto the  jack posts. Then, turn the plug clockwise until the jack posts are fully seated within the  plug slot.     • Threaded Coupling Connections: Engage the plug onto the jack threads, and then turn ...
  • Page 39: Type 'F

    CDM-800 Gateway Router Revision 1 Rear Panel Connections MN-CDM800 3.1.1.4 Type ‘F’ Type ‘F’ connectors feature a Threaded Coupling design similar to  Type ‘TNC’, Type ‘N’, and Type ‘SMA’ connectors.         3.1.1.5 Type ‘SMA’ (Subminiature Version ‘A’) Type ‘SMA’ connectors feature a Threaded Coupling design similar  to Type ‘TNC’, Type ‘N’, and Type ‘F’ connectors.         3.1.2 D-Subminiature Cable Connections Type ‘D’ Connection Type  Example  Chassis Receptacles:  Female (top)  Male (bottom)    Type ‘D’ Cable with Jack Screws  (female shown) ...
  • Page 40: Circular Cable Connections

    CDM-800 Gateway Router Revision 1 Rear Panel Connections MN-CDM800 Connection  Instructions:  Orient  the  plug  to  the  receptacle  in  the  proper  position.  Press  firmly  into  place.  Use  the  jack  screws  to  secure  the  plug  to  the  receptacle  jack  nuts.  Do  not  over‐...
  • Page 41: Cabling Connections

        (Top) Standard AC Unit   (Bottom) Optional 48V DC Unit Figure 3-3. CDM-800 Cabling Connections The  CDM‐800  rear  panel  connectors,  shown  here  in  Figure  3‐1,  provide  all  necessary  external  connections  between  the  unit  and  other  equipment.  The  table  that  follows  summarizes  the  connectors provided here, grouped according to service function.    Connector Group...
  • Page 42: If Connector Group

    CDM-800 Gateway Router Revision 1 Rear Panel Connections MN-CDM800 3.2.1 IF Connector Group 3.2.1.1 ‘L-BAND Tx’ Connector   THERE MAY BE DC VOLTAGES PRESENT ON THE TYPE ‘N’ TX IF CONNECTOR, UP TO A  MAXIMUM OF 48 VOLTS.        Connector Type Name Description Direction   Type ‘N’ 50Ω Female  L‐BAND Tx  Tx IF Signal, L‐Band  Out        3.2.1.2 ‘70/140 Tx’ IF Connector  ...
  • Page 43: Terrestrial Data Connector Group

    CDM-800 Gateway Router Revision 1 Rear Panel Connections MN-CDM800 3.2.2 Terrestrial Data Connector Group 3.2.2.1 ‘GE1’ ‘GE2’ (Gigabit Ethernet) Connectors   Connector Type  Name    Direction      RJ‐45 female modular jacks  GE1, GE2  In/Out      • These  interfaces  operate  at  10/100/1000  Mbps  @  full  duplex  (10/100  Mbps  @ ...
  • Page 44: Utility Connector Group

    CDM-800 Gateway Router Revision 1 Rear Panel Connections MN-CDM800 3.2.4 Utility Connector Group 3.2.4.1 ‘TERM’ Connector   This RJ‐12 female modular jack is unused at this time.    3.2.4.2 ‘FE’ (Fast Ethernet) Connector   Connector Type Name Direction      RJ‐45 female modular jack  In/Out  FE      • This interface operates at 10/100 Mbps, half and full duplex, auto‐negotiating.  • The maximum Ethernet packet size is 1522 bytes (including Ethernet headers and  CRC) ...
  • Page 45: Console' Interface Connector

    CDM-800 Gateway Router Revision 1 Rear Panel Connections MN-CDM800 3.2.4.4 ‘CONSOLE’ Interface Connector Connector Type Name Direction  Type ‘D’ 9‐pin male  CONSOLE  In/Out    This interface is used for EIA‐232 communications. It is intended for connection to an  M&C computer or VT (Video Terminal) device.  Table 3-2. CONSOLE Connector Pinout Pin #  Description  Direction  1  GROUND  –  6  RESERVED ‐ DO NOT CONNECT TO THIS PIN  –  2  EIA‐232 TRANSMIT DATA  OUT  7 ...
  • Page 46: Ground And Power Connections

      PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be connected  to the protective earth connection at all times. It is therefore imperative that the unit  is properly grounded, using the ground stud provided on the unit rear panel, during  installation, configuration, and operation.                    (Top) Standard AC Unit   (Bottom) Optional 48V DC Unit Figure 3-4. CDM-800 Chassis Ground Interface   Use the #10‐32 stud, located adjacent to the power interface, for connecting  a common chassis ground among equipment.        The AC power interface provides the safety ground.     3–10...
  • Page 47: 230V Alternating Current (Ac) Power Interface (Standard)

    Figure 3-5. CDM-800 AC Power Interface 3.3.2.1 AC Operation – Applying Power                       Figure 3-6. Applying AC Power to the CDM-800 To apply AC power to the CDM‐800:    • First, plug the provided AC power cord female end into the unit.    • Then, plug the AC power cord male end into the user‐supplied power source.    • Finally, switch the unit ON.   3–11...
  • Page 48: Ac Operation - Replacing Fuses

                                  Figure 3-7. Replacing CDM-800 AC Fuses   To replace the fuses:    • First, unseat the fuse holder from the IEC power module.    o Use the slot to pry the holder outward from the IEC power module.     o Pull the holder straight out, and then swing the holder away from the module.     • Then, remove and replace the fuses as needed.    o Use T2.5A (2.5 Amp) fuses for standard operation.   ...
  • Page 49: Direct Current (Dc) Power Interface (Optional)

                        Figure 3-9. Applying DC Power to the CDM-800 To apply DC power to the CDM‐800:    • First,  connect  the  user‐supplied  (+)  and  (–)  DC  power  leads  to  their  respective  terminals. Number 18 AWG minimum wires are recommended.     • Then, connect the user‐supplied DC power leads to the power source.    •...
  • Page 50: Dc Operation - Replacing Fuses

                        Figure 3-10. Replacing CDM-800 DC Fuses   To replace the fuses:    • First,  unscrew  either  fuse  holder  from  its  receptacle.  Then,  remove  and  replace  the  fuse:    o Use T3A (3 Amp) fuses for standard operation    o Use T5A (5 Amp) fuses when a Block Upconverter (BUC) is installed. ...
  • Page 51: Chapter 4. Updating Firmware

    Chapter 4. UPDATING FIRMWARE Updating Firmware via the Internet   TO ENSURE OPTIMAL PERFORMANCE, IT IS IMPORTANT TO OPERATE THE CDM‐800  WITH ITS LATEST AVAILABLE FIRMWARE.     The CDM‐800 Gateway Router is factory‐shipped with its latest version of operating firmware. If  a firmware update is needed, it can be acquired over satellite; by download from the Comtech  EF Data Web site (www.comtechefdata.com); or from Comtech EF Data Customer Support  during normal business hours via e‐mail or on CD by standard mail delivery.    The CDM‐800 Firmware Update process is as follows:    • Perform the update without opening the CDM‐800 – over satellite or by connecting the  rear panel ‘FE’ 10/100 Fast Ethernet port to the Ethernet port of a user‐supplied PC.     • Download the firmware update via the Internet to the user PC.     • Transfer the firmware update, via File Transfer Protocol (FTP), from the user PC to the  CDM‐800.    4–1...
  • Page 52: Getting Started: Preparing For The Firmware Download

    • Port Flow Control = NONE  • Display New line Rx/Tx: CR  • Local Echo = ON        C. On the CDM‐800: Turn on the power.             (Left) Standard CDM-800 115V/230V AC Unit   (Right) Optional CDM-800 48V DC Unit   D. On the PC: Review and record the information displayed on the CDM‐800 Command  Line Interface (CLI):    • Management IP Address (e.g., default is 192.168.1.10/24)  • Firmware Number and Revision Letter (e.g., FW‐0000430J)  • Firmware Release Version (e.g., 1.3.2) ...
  • Page 53 CDM-800 Gateway Router Revision 1 Updating Firmware MN-CDM800                           See  Chapter  6.  SERIAL‐BASED  REMOTE  PRODUCT  MANAGEMENT  for  information  and  instructions  on  using  the  CDM‐800  Serial  Command  Line  Interface. ...
  • Page 54 CDM-800 Gateway Router Revision 1 Updating Firmware MN-CDM800 There are several ways the user may use create a temporary folder on a Windows‐based PC:    A. Use the Windows Desktop to create and rename the temporary folder.    • Right‐click anywhere on the desktop to open the popup submenu, and then select  New > Folder to create the temporary folder. The new folder will be created on the  desktop.    • Right‐click  on  the  new  folder  and  then  select  Rename  from  the  popup  submenu.  Rename this folder to "temp" or some other convenient, unused name.                ...
  • Page 55 CDM-800 Gateway Router Revision 1 Updating Firmware MN-CDM800             D. Use Windows Command‐line to create the temporary folder.    • First,  click  [Start]  on  the  Windows  taskbar,  and  then  click  the  Run...  icon  (or,  depending on Windows OS versions prior to Windows 95, click the MS‐DOS Prompt  icon from the Main Menu).     • Next, open a Command‐line window…    o For Windows 95 or Windows 98 – Type “command”. ...
  • Page 56: Downloading And Extracting The Firmware Update

    CDM-800 Gateway Router Revision 1 Updating Firmware MN-CDM800 Downloading and Extracting the Firmware Update 1. First, download the firmware update archive file from the Comtech EF Data Web site:    A. Go online to www.comtechefdata.com.    B. On the Main page – under Support Information or the Support tab, select the Software  Downloads hyperlink.    C. On the Software Downloads page – click Download Flash and Software Update Files.    D. On the Flash Updates Index page – select the (Select a Product Line) Advanced VSAT  Series hyperlink.    E. On the Advanced VSAT Solutions product page – select the CDM‐800 product hyperlink.    F. Select the appropriate firmware archive EXE or ZIP file download hyperlink.    • About Firmware Numbers, File  Versions, and Formats: The Comtech  EF ...
  • Page 57 CDM-800 Gateway Router Revision 1 Updating Firmware MN-CDM800 o Click [Open] to turn over file extraction to the user‐supplied utility program. Be  sure to extract the firmware files to the “temp” folder created earlier.     o Click  [Save]  to  open  the  ‘Save  As’  window.  Be  sure  to  select  and  [Save]  the  archive *.exe or *.zip file to the “temp” folder created earlier.    o Otherwise, click [Cancel] to quit and exit the file download process.                 ...
  • Page 58: Performing The Ethernet Ftp Upload Procedure

    CDM-800 Gateway Router Revision 1 Updating Firmware MN-CDM800 • Type  “dir”  to  list  the  files  extracted  to  the  temporary  directory  from  the  downloaded archive file.    The firmware files have been successfully downloaded and are now available for transfer to  the CDM‐800.  Performing the Ethernet FTP Upload Procedure   To proceed with the firmware update procedure, assumptions are made that:    • The CDM‐800 is connected to a user‐supplied, Windows‐based PC, and:    o The PC serial port is connected to the CDM‐800 ‘CONSOLE’ port. ...
  • Page 59 CDM-800 Gateway Router Revision 1 Updating Firmware MN-CDM800 • Once the Management IP address is known – use Command‐line to PING: Type “ping  xxx.xxx.xxx.xxx” at the Command‐line prompt (where ‘xxx.xxx.xxx.xxx’ is the unit  Management IP Address).     The  response  should  confirm  whether  or  not  the  unit  is  properly  connected  and  communicating.    2. Use Command‐line to transfer (FTP) the files from the user PC to the CDM‐800:    • Type  "ftp  xxx.xxx.xxx.xxx"  (where  ‘xxx.xxx.xxx.xxx’  denotes  the  Management  IP ...
  • Page 60 CDM-800 Gateway Router Revision 1 Updating Firmware MN-CDM800 B. Reboot the CDM‐800:    • Go to either the Web Server Interface ‘Admin | Firmware’ page or the ‘Utility |  Reboot’ page.     • Click [Reboot] (in the System Reboot  section) and [OK] when prompted, and  then wait while the CDM‐800 reboots.     The CDM‐800 is now operating with its latest firmware. The firmware update process is now  complete.  4–10...
  • Page 61: Chapter 5.  Ethernet-Based Remote Product Management

    Chapter 5. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT Introduction Ethernet‐based  Remote  Product  Management  of  the  CDM‐800  Gateway  Router  is  available  using the rear panel ‘FE’ RJ‐45 10/100 BaseT Fast Ethernet M&C port.      1. TO PROCEED WITH ETHERNET‐BASED REMOTE PRODUCT MANAGEMENT (SNMP  OR WEB SERVER), ASSUMPTIONS ARE MADE THAT:    • The CDM‐800 is operating with the latest version firmware files.    • The CDM‐800 is connected to a user‐supplied, Windows‐based PC as follows:   o The  PC  serial  port  is  connected  to  the  CDM‐800  rear  panel  ‘CONSOLE’  port with a user‐supplied serial cable. ...
  • Page 62: Ethernet Management Interface Protocols

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 Ethernet Management Interface Protocols The  user  PC  facilitates  access  to  Ethernet‐based  remote  monitor  and  control  (M&C)  of  the  CDM‐800 through two separately‐operated protocols:    • Simple  Network  Management  Protocol  (SNMP).  This  requires  a  user‐supplied  Network ...
  • Page 63: Snmp Interface

      MIB File/Name Description (where ‘x’ is revision letter) ComtechEFData.mib ComtechEFData MIB file gives the root tree for ALL Comtech EF Data products and consists of only the following OID: ComtechEFData Root MIB file Name: comtechEFData Type: MODULE-IDENTITY OID: 1.3.6.1.4.1.6247 Full path: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtechEFData(6247)
  • Page 64: Web Server (Http) Interface

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 The user defines two Community Strings for SNMP access:     • Read Community  default = public  • Write Community   default = private      For  proper  SNMP  operation,  the  CDM‐800  MIB  files  must  be  used  with  the  associated version of the CDM‐800 router M&C. Refer to the CDM‐800 FW Release  Notes for information on the required FW/SW compatibility.  Web Server (HTTP) Interface A  user‐supplied  Web  browser  allows  the  full  monitoring  and  control  (M&C)  of  the  CDM‐800 ...
  • Page 65: Web Server Interface - Operational Features

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.2 Web Server Interface – Operational Features 5.4.2.1 Virtual Front Panel           The CDM‐800 Web Server Interface features a read‐only ‘Virtual Front Panel’ (VFP) at the top of  every  page.  This  section  emulates  the  CDM‐800  front  panel  real‐time  LED  operation.  These ...
  • Page 66: Feature Selection

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 All  execution  buttons  serve  the  same  purpose  –  to  save  the  configuration  changes  to  flash  memory, or to execute an update of the active page display.     Always  make  sure  to  click  the  execution  button  before  selecting  another  Web   ...
  • Page 67: Web Server Interface - Menu Tree

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.3 Web Server Interface – Menu Tree The tree diagram blocks that are marked with (*) denote pages that are functional  only when that particular  FAST feature has been purchased and activated. Blocks    that are marked with (**) denote pages that are functional only when a VIPERSAT  MANAGEMENT SYSTEM (VMS) is installed and is recognized as operational.    The CDM‐800 Web Server Interface features five (5) navigation tabs (shown in blue):     • Home  • Admin  • Configuration  • Status  • Utility    Beyond  this  top‐level  row  of  navigation  tabs,  primary  page  tabs  (green)  and  nested  page  tabs ...
  • Page 68: Home | Home

    MN-CDM800 5.4.4 Web Server Interface Page Descriptions Access to and availability of certain CDM-800 Web Server Interface pages is dependent upon the FAST options purchased for operation as well as the detected presence of auxiliary products (e.g., VIPERSAT Management System, Redundancy Switches, etc.) installed and configured for use with the CDM-800.
  • Page 69: Home | Contact

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.1.2 Home | Contact Use  this  page  to  reference  basic  contact  information  needed  to  reach  Comtech  EF  Data  Sales  and Customer Support via phone, fax, or Web/e‐mail hyperlinks.        Figure 5‐2. Home | Contact page    5–9...
  • Page 70: Admin | Access

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.2 Admin (Administration) Pages Use these pages to set up user access, manage the firmware load preferences, and activate FAST  features.    The Admin pages are available only to users who have logged in using the Administrator Name and Password.   Click the Access, SNMP, FAST, Firmware, Auto Logout, or VMS tab to continue.    5.4.4.2.1 Admin | Access Use ...
  • Page 71: Admin | Snmp

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.2.2 Admin | SNMP   Sect. 5.3 SNMP Interface  Use this page to set up and return administration information for the CDM‐800 Simple Network  Management Protocol (SNMP) feature.                      Figure 5‐4. Admin | SNMP page  SNMP Configuration   THE SNMP TRAP DESTINATION IP ADDRESS FEATURE IS A FUTURE OFFERING. IT IS NON‐ FUNCTIONAL AT THIS TIME.     • Enter  an  SNMP  Read  Community  string.  The  SNMP  Read  Community  string  can  be  any ...
  • Page 72: Admin | Fast

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.2.3 Admin | FAST   Appendix A. FAST  The  CDM‐800  has  a  number  of  optional  features  that  may  be  activated  after  purchase  of  the  unit. Fully Accessible System Topology (FAST) Access Codes are unique authorization codes that  may be purchased from Comtech EF Data during normal business hours, and then loaded into  the unit using this page.           ...
  • Page 73 Enabled/Disabled Tx Frequency IF (50-180 MHz) and L-Band (950-2150 MHz) FAST Upgrade Serial Number (read‐only) – The serial number of the unit is required by Comtech EF Data when  ordering FAST option upgrades. Take note of this number before contacting Comtech EF Data to  order a CDM‐800 FAST option upgrade.    FAST  Code  –  Once  a  FAST  upgrade  order  is  placed  and  confirmed,  the  Comtech  EF  Data  sales  representative will provide a 20‐digit FAST Access Code. To perform the CDM‐800 FAST option  upgrade:    Step  Task  1  Use the FAST Configuration table to view the currently installed features.  ...
  • Page 74: Admin | Firmware

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.2.4 Admin | Firmware   Chapter 4. UPDATING FIRMWARE  Use  this  page  to  select  which  image  (boot  Slot  #)  is  to  be  designated  as  the  active  running  firmware image – i.e., the version loaded for operation upon power‐up or soft reboot.    Figure 5‐6. Admin | Firmware page  Slot Information This read‐only status section displays operating status for the firmware versions loaded into Slot ...
  • Page 75: Admin | Auto Logout

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.2.5 Admin | Auto Logout Use this page to incorporate the Auto Logout security measure.         Figure 5‐7. Admin | Auto Logout page  Auto Logout Configuration Set an automatic logout time to safeguard access to an already logged‐in unit:    • Enter a value from 1 to 15 minutes into the Logout Time box to configure this feature.     • Enter a value of 0 to disable this feature.    Click [Submit] to save the desired configuration.    When  Auto  Logout  is  configured,  the  active  session  terminates  if  the  unit  remains  idle  (i.e., ...
  • Page 76: Admin | Vms

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.2.6 Admin | VMS   The  VMS  page  is  operational  only  when  the  optional  VIPERSAT  MANAGEMENT  SYSTEM (VMS) is installed and operational.  VMS v3.x.x VIPERSAT Management System User Guide (CEFD P/N MN/22156)                          ...
  • Page 77 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800   • Management  Multicast  IP  Port  –  The  Multicast  Address  is  the  NMS  Multicast  IP  address  assigned to all Gateway Routers in the Vipersat network that are managed by the VMS. This  address must match the VMS Transmit Multicast Address.     Typical for each item, click [Submit] to save the setting change.  Vipersat Management System Status This  read‐only  section  provides  available  information  on  the  VMS  IP  Address,  Registration ...
  • Page 78: Configuration | Interface

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.3 Configuration Pages Use the nested ‘Configuration’ pages to configure all unit parameters. Click the Interface, Mod,  ARP, Routing, Compression, or WAN tab to continue.  5.4.4.3.1 Configuration | Interface Click the FE Mgt, GE‐1, or GE‐2 tab to continue.  5.4.4.3.1.1 Configuration | Interface | FE Mgt Use this page to configure the rear panel ‘FE’ 10/100 BaseT Fast Ethernet M&C port.         Figure 5‐9. Configuration | Interface | FE Mgt Page  FE – Management Interface The acceptable/valid operating ranges for items in this section are provided in parentheses.    • MAC Address (read‐only) – The MAC Address cannot be changed. ...
  • Page 79: Configuration | Interface | Ge-1 Or Ge-2

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 * Auto is the recommended configuration selection.      • Negotiated Link Mode (read‐only) – The actual negotiated line speed and duplex setting for  the FE Interface is displayed here.    The viewable settings are:    o 10 BaseT / Full Duplex o 100 BaseT / Full Duplex o 10 BaseT / Half Duplex o 100 BaseT / Half Duplex  ...
  • Page 80: Configuration | Mod (Modulator)

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.3.2 Configuration | Mod (Modulator)   The upper range of Symbol Rate selection requires activation of the ‘TRANSMIT SYMBOL  RATE’ FAST option.    Use this page to configure CDM‐800 Tx modulator operations.      Figure 5‐11. Configuration | Mod page  Modulator The acceptable/valid operating range for each item in this section is provided in parentheses.    • MODCOD  /  Data  Rate  (read‐only)  –  This  section  displays  the  effective  data  rate  of  the ...
  • Page 81 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800   • FEC Type – At present, DVB‐S2 is the sole available FEC type.    • Tx Frequency (950 to 2150 MHz for L‐Band, 50 to 180 MHz for IF) – Enter the Tx frequency  in MHz.    • Frame – Use the drop‐down menu to select the Frame type as Normal or Short. This field  will be forced to Normal if any MODCOD enabled in Group QoS (see Sect. 5.4.4.3.5.1) has a  code rate of 9/10.    • Pilots (read‐only) – This feature is always ON.     • Gold  Code  (000000  to  262141)  –  The  Gold‐n  Index  indicates  the  Physical  Layer  spreading ...
  • Page 82: Configuration | Arp

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.3.3 Configuration | ARP Use this page to configure the CDM‐800 ARP (Address Resolution Protocol) parameters.           Figure 5‐12. Configuration | ARP page  Add Static ARP Enter  the  desired  IP  and  MAC  addresses.  Click  [Add  Entry]  when  done.  The  Index  column  automatically  increments  to  the  next  available  number  when  the  specified  static  ARP  entry  is ...
  • Page 83: Configuration | Routing | Routes

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800   • Index (read‐only) – This is the internal table index and it cannot be edited.    • IP – Entry IP Address, format XXX.XXX.XXX.XXX.    • MAC – Entry MAC Address, format YY:YY:YY:YY:YY.    • Type (read‐only) – The entry Type is identifiable as Static or Dynamic and cannot be edited.    Make the desired IP and MAC Address edits. Click [Submit Changes] to save.  5.4.4.3.4 Configuration | Routing | Routes Use this page to enter static routes for IP traffic over the satellite or to another device on the  LAN.          Figure 5‐13. Configuration | Routing | Routes page  Add New Route Use this section to directly add a Route Table entry: ...
  • Page 84 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 • Description – Enter a label string in this text box. This label helps to maintain the network.  The assigned name must be unique and cannot contain any whitespace.    • Dest. IP/Mask – Enter a Destination IP Address/Mask in the form XXX.XXX.XXX.XXX/YY.   Multicast addresses must have a subnet of 32.  • Interf. – Use the drop‐down menu to select the Interface as toWAN or toLAN.    • Next Hop IP – Enter the desired Next Hop IP Address for toLAN routes. Note that no Next  Hop entry is needed for toWAN routes.    • WAN  Label  –  This  label  allows  traffic  to  a  defined  remote  designation  to  be  passed.  The ...
  • Page 85: Configuration | Compression

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.3.5 Configuration | Compression   Use  the  ‘Configuration  |  Routing  |  Routes’  page  (Sect.  5.4.4.3.4)  to  enable  or    disable Header and Payload Compression operation.    Use  this  page  to  configure  the  optional  Payload  and  Header  Compression  FAST  feature,  if ...
  • Page 86: Configuration | Wan | Qos

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.3.5.1 Configuration | WAN | QoS The appearance of this page changes depending on the selected QoS Control Mode.                                               ...
  • Page 87 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800                                       (Top) Page with QoS Control Mode = Max/Pri(ority)  (Bottom) Page with QoS Control Mode = Min/Max (Banner, VFP, Menu Bar not shown)  Figure 5‐16. Configuration | WAN | QoS page (continued)    5–27...
  • Page 88 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800   The following page sections are typical for all active QoS configurations.  Add / Change / Delete Group   Use the controls provided at the top and far right of this section to create / add new QoS  configuration groups. The remainder of this section displays previously created groups,  numbered in the order of creation.    The individual columns are defined as follows:    • Index – The automatically‐assigned internal index number for the group is identified here.    • Name – This is the name assigned to the group. It must be unique across all groups.    • CIR (kbps) – This is the Committed Information Rate for the QoS Group. The QoS Manager  will try to guarantee this date rate for all traffic that matches this group.    • MIR (kbps) – This is the Maximum Information Rate for the QoS Group. The QoS Manager  will not allow traffic that matches this Group to send more than this data rate.    •...
  • Page 89: Group Table

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 Comments) standards. The ‘Configuration | WAN | QoS’ page appears as shown in the  bottom example in Figure 5‐15.    o Max/Pri(ority) – This mode provides multi‐level traffic prioritization with the ability to  limit maximum traffic per priority class. The ‘Configuration | WAN | QoS’ page appears  as shown in  the top example in Figure 5‐16.    o Min/Max  –  This  mode  provides  a  Committed  Information  Rate  (CIR)  to  each  user‐ defined  class  of  traffic  with  the  ability  to  allow  a  higher  burstable  rate  depending  on ...
  • Page 90 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 Remote Attribute   This table displays Remote Attribute Value for the active group.    • Index – The automatically‐assigned internal index number for the group is identified here.    • Type – At present, Subnet is the only available attribute.    • Value – This is the assigned subnet, in xxx.xxx.xxx.xxx/yy format.  Differentiated Services Table The Differentiated Services table appears only when QoS Control Mode = DiffServ.  From left to right:    • Index – The automatically‐assigned specific rule internal index number is identified here.    • Priority – IP traffic is prioritized based upon the DSCP (DiffServ Code Points) Class Selector  Precedence.    • Per‐Hop Behavior (PHB) – This is the Traffic class that determines how packets will be  forwarded.   ...
  • Page 91 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 The  option  is  provided  to  configure  each  queue  to  one  of  the  following  attributes.  The    acceptable/valid operating ranges are provided in this section in parentheses, where applicable.   • Service Rate (Kbps) (0.000 / (Tx Data Rate)) – The minimum bandwidth will be served first  among  the  Assured  Forwarding  (ASFD)  classes  in  case  of  bandwidth  availability  once  Class ...
  • Page 92 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 QoS Rules Per Group Table (Edit) This read‐only section displays all existing QoS Rules Per Group Table entries.      For the ‘Max/Pri(ority)’ page:          For the ‘Min/Max’ page:          From left to right:    • Index – The automatically‐assigned specific rule internal index number is identified here.    • Protocol – The protocol for the specific rule is identified here.    • Src IP/Mask – The Source IP Address/Mask is displayed here in the form  XXX.XXX.XXX.XXX/YY. ...
  • Page 93 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 Add / Delete Per Group QoS Rule Refer to the QoS Rules Per Group (Edit)Table section for the description of each column.    • To delete an existing rule: For either page, Enter Rule Index to Delete. Click [Delete Rule]  when done. This deletes the specified entry from the QoS Rules Per Group Table. • To add a new rule: For either page, enter or select the desired information. Click [Add Rule]  when done. The index will automatically increment to the next available number when the  new rule is added.    • For the ‘Max/Pri(ority)’ page:            o Priority – To define a priority based upon the DSCP (DiffServ Code Points) Class Selector  Precedence, use the drop‐down menu to designate a priority for this rule from 1  (Highest) to 8 (Lowest).    o WRED – Use the drop‐down menu to set Weighted Random Early Detection as Enable ...
  • Page 94: Status | Statistics | Traffic

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.4 Status Pages The Status pages provide status, event logging, and operational statistics windows.    Click the Statistics or Monitor tab to continue.  5.4.4.4.1 Status | Statistics Pages   Click the Traffic, Router, Compression, or QoS tab to continue.  5.4.4.4.1.1 Status | Statistics | Traffic Use  this  page  to  view  read‐only,  abridged  status  windows  pertaining  to  the  basic  operational ...
  • Page 95 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 Column Description UC Pkts Rcvd Unicast packets received. MC Pkts Xmitted Multicast packets transmitted. MC Pkts Rcvd Multicast packets received. Current Xmitted (Kbps) Most recent transmitted data rate (in kilobits per second).
  • Page 96: Status | Statistics | Router

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.4.1.2 Status | Statistics | Router Use this page to view cumulative traffic information.      Figure 5‐18. Status | Statistics | Router page  Clear Statistics Click [Clear] to clear all operational statistics from the buffer.  Interface Counters / Router Counters / Management Counters For each section: Click [Refresh] to update the section with its latest available statistics.  5–36...
  • Page 97: Status | Statistics | Compression

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.4.1.3 Status | Statistics | Compression   This page is operational only when the optional Tx and Rx Payload and Header are  installed and enabled.    Use  this  page  to  view  read‐only  cumulative  WAN,  Payload  Compression,  and  Header  Compression statistics.    Figure 5‐19. Status | Statistics | Compression page  Clear Compression Counters Click [Clear] to clear all compression statistics from the buffer.   WAN / Payload Compression / Detailed Compression Statistics Click [Refresh] to update the page with the latest available statistics. ...
  • Page 98: Status | Statistics | Qos

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.4.1.4 Status | Statistics | QoS The appearance of this page changes depending on the selected QoS Control Mode.                                               ...
  • Page 99 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 The Clear Statistic, Total For All Groups, Group Table, and Clear QoS Counters  sections are typical for all ‘Status | Statistic | QoS’ page configurations.   Clear Statistic     Click [Clear] to clear all operational statistics from the buffer.  Total For All Groups           See the ‘Configuration | WAN | QoS’ page for the definition of the terms used in this table.    Click [Refresh ] to update this section with the latest available statistics.  Group Table This section is active only when QoS Control Mode is set to DiffServ.    See the ‘Configuration | WAN | QoS’ page for the definition of the terms used in this section.    Click Select to activate a desired group (when more than one group has been created). Otherwise,  if only a single group is found, operation defaults to this selection.    Click [Refresh] to update this section with the latest available statistics.  Clear QoS Counters  ...
  • Page 100: Qos Statistics

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 QoS Statistics   The  appearance  of  the  QoS  Statistics  section  differs  depending  on  the  active  page  configuration.  See  the  ‘Configuration  |  WAN  |  QoS’  page  for  the  definition  of  the ...
  • Page 101: Status | Statistics | Vcm (Variable Coding And Modulation)

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.4.1.5 Status | Statistics | VCM (Variable Coding and Modulation) VCM  allows  different  MODCODs  for  different  users  and  applications  sharing  a  common  outbound.  The  MODCODs  are  statically  assigned  based  on  link  budget.  Use  this  page  to  view ...
  • Page 102 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 Column Description Percentage of Total (%) Percentage of the total number of DVB-S2 base band frames transmitted. Average Throughput (kbps) Amount of data in Kbps being transmitted through this MODCOD.
  • Page 103: System Monitor

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.4.2 Status | Monitor page Use  this  page  to  view  the  unit  temperature,  alarms  summary,  plus  a  scrollable  read‐only  window that displays any events and alarms as logged by the unit during normal operation.    Figure 5‐22. Status | Monitor page  System Monitor This section provides the operating temperature of the unit (°C). Click [Refresh] to update this  display.  Alarms This section provides an overall tally of the Unit, Tx, and Traffic Ethernet alarms compiled since  the logging buffer was last cleared.   ...
  • Page 104: Utility | Utility

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.5 Utility Pages Click the Utility or Reboot tab to continue.  5.4.4.5.1 Utility | Utility Use  this  page  to  access  a  variety  of  top‐level  system  operation  controls,  stored  unit  configurations, and test utilities.       Figure 5‐23. Utility | Utility page    5–44...
  • Page 105 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 Modem • Unit Name – The product (e.g., CDM‐800) is identified here.    • System Contact / System Location – E‐mail and telephone contact information for Comtech  EF Data Customer Support are provided here.       Enter the desired settings. Click [Submit] to save.    • Set Time (hh:mm:ss) – Use the HH:MM:SS time format to set the time, where HH=hour [00  to 23]; MM=minutes [00 to 59]; and SS=seconds [00 to 59]).    • Set Date (dd/mm/yy) – Use the DD/MM/YY European time format to set the date, where  DD=day [01 to 31]; MM=month [01 to 12]; and YY=year [00 to 99].    Set the time and date, and then click [Submit] to save.    • Circuit ID – Enter a Circuit ID string consisting of 4 to 24 characters, and then click [Submit]  to save.    • G.703 Clock Extended Mode – Use the drop‐down menu to select this operating mode as Off  or On, and then click [Submit] to save.    •...
  • Page 106 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 o Then, use the top (Save) Select Location dropdown to select 1 through 10.    o Finally, click [Save Configuration] to store the configuration settings.     • To load (recall) a configuration set:     o First, use the bottom (Load) Select Location dropdown to select 1 through 10.     o Then, click [Load Configuration] to recall the selected configuration settings.  BERT Config (Where BERT is the acronym for Bit Error Rate Test) Use the drop‐down menus to:    • Configure the Tx BERT State as On or Off.    • Configure the Tx or Rx BERT Pattern as 2^23‐1 (2 ‐1) or 2047.    • Set Error Insert(ion) as either Off or 10E‐3.    Click [Submit] to save the BERT settings and execute the test.   ...
  • Page 107: Utility | Reboot

    CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 5.4.4.5.2 Utility | Reboot Use this page to perform a soft reboot of the CDM‐800. Note that the function of this page is  identical to the System Reboot section of the ‘Admin | Firmware’ page described earlier.                           Figure 5‐24. Utility | Reboot page  System Reboot Click [Reboot] to reboot the unit. A dialogue box  appears  to  prompt  continuation  or  cancellation  of the reboot process:   ...
  • Page 108 CDM-800 Gateway Router Revision 1 Ethernet-based Remote Product Management MN-CDM800 Notes:                                                      5–48...
  • Page 109: Chapter 6. Serial-Based Remote Product Management

    Chapter 6. SERIAL-BASED REMOTE PRODUCT MANAGEMENT Introduction Serial‐based Remote Product Management of the CDM‐800 Gateway Router is available using the rear panel ‘CONSOLE’ port.    1. To proceed with Serial‐based Remote Product Management, assumptions are made that:  • The CDM‐800 Gateway Router is operating with the latest version firmware files.    • The CDM‐800 is connected to a user‐supplied Windows‐based PC as follows:  o The PC serial port is connected to the CDM‐800 rear panel ‘CONSOLE’ port using a user‐supplied serial cable.    o The PC Ethernet port is connected to the CDM‐800 rear panel ‘MANAGEMENT | FE’ 10/100 BaseT Ethernet port  with a user‐supplied hub, switch, or direct Ethernet cable connection.    o The PC is running a terminal emulation program (for operation of the CDM‐800 Serial Command Line Interface)  and a compatible Web browser (for operation of the CDM‐800 Web Server Interface).  • The CDM‐800 Management IP Address has been noted using the CDM‐800 Serial Command Line Interface (CLI).    6–1...
  • Page 110                 Figure 5-1. CDM-800 Serial Interface Example   CDM‐800 Serial Remote Product Management is available through the EIA‐232 operational interface, where the ‘Controller’ device (the  user PC or an ASCII dumb terminal) is connected directly to the ‘Target’ device (the CDM‐800 Gateway Router, via its DB‐9M ‘CONSOLE’  port).  This  connection  makes  possible  serial  remote  monitor  and  control  (M&C)  of  the  CDM‐800  through  its  Serial  Command  Line  Interface (CLI).    Through this EIA‐232 connection (for the control of a single device), data is transmitted in asynchronous serial form, using ASCII characters.  Control and status information is transmitted in packets of variable length in accordance with the structure and protocol defined later in ...
  • Page 111: Remote Commands And Queries Overview

    CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 When  the  user‐supplied  terminal  emulator  program  is  configured  correctly,  upon  power‐up  of  the  CDM‐800,  the  CLI  Info  Screen  appears,  followed  by  the  CLI  command  prompt  CDM‐800>.  From  here,  type  “help[cr]”  or  “?[cr]”  (without  the  quotes)  to  display  the ...
  • Page 112: Start Of Packet

    CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 Controller-to-Target (Issued Command or Query) Start of Packet Target Address Address Delimiter Instruction Code Code Qualifier Optional Arguments End of Packet < 0000 (default) = or ? Carriage Return ASCII code 60...
  • Page 113: Target Address

    CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 6.2.2.2 Target Address In EIA‐232 applications, this value is set to 0000.     The Target Address designates the packet destination. The Controller does not have its own address. After the Controller sends a packet with the designated Target Address, the Target responds to the Controller, using this same address, to indicate the source of the packet.
  • Page 114: Instruction Code Qualifier

    CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 6.2.2.5 Instruction Code Qualifier This is a single character that further qualifies the preceding instruction code. Code Qualifiers obey the following rules:    From Controller‐to‐Target, the only permitted characters are:    Character Definition This character is used as the Assignment Operator (AO). It establishes that the Instruction Code that precedes it is to (ASCII code 61) be used as a command to assign or configure operation.
  • Page 115: Optional Message Arguments

    CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 Character Definition If the Controller sends an instruction code that the Target does not recognize, the Target responds by echoing the invalid instruction, followed by ! (ASCII code 33) Example: CMD!
  • Page 116: Remote Commands And Queries

    CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 Remote Commands and Queries The Serial Command Line interface (CLI) (the Controller), shown previously in Figure 5‐1,  is used to issue remote commands and queries  to the CDM‐800 (the Target). From the CLI command prompt CDM‐800> type in the command or query packet, using the format  explained previously, for transmission to the CDM‐800.    For example: CDM‐800><0000/LC1=3[cr]    The table that follows provides a ‘quick reference‘ to the Instruction Codes available at present for M&C of the CDM‐800. The ‘C’ and ‘Q’  columns, when marked with an ‘X’, denote whether that Instruction Code is Command Only, Query Only, or Command and Query.    INSTRUCTION  USED TO...  C  Q  Page  CODE  DPW  Set default passwords  X    5‐9  IG1  Set or query the IP Address and network prefix for the GE‐1 10/100/1000 Gigabit Ethernet Port  X  X  5‐9  IG2 ...
  • Page 117 CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 These Instruction Codes are explained in complete detail in the tables that follow. Note that the Target‐to‐Controller Instruction Code  Qualifiers, described earlier, that appear in the “Response to Command” column carry the following meanings:    =   Message OK.  ?   Received OK, but invalid arguments were found.  *   Message OK, but not permitted in current mode.  #   Message OK, but unit is not in Remote mode.  !   Invalid instruction.    Command Query Parameter Number of Response to (Instruction Description of Arguments (Instruction & Response to Query Type Arguments Command & Qualifier)
  • Page 118 CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 Command Query Parameter Number of Response to (Instruction Description of Arguments (Instruction & Response to Query Type Arguments Command & Qualifier) Qualifier) GE2 Address IG2= 18 bytes numerical Command or Query.
  • Page 119 CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 Command Query Parameter Number of Response to (Instruction Description of Arguments (Instruction & Response to Query Type Arguments Command & Qualifier) Qualifier) Management 12 bytes, alpha- Query only. MAC? MAC=aabbccddeeff...
  • Page 120 CDM-800 Gateway Router Revision 1 Serial-based Remote Product Management MN-CDM800 Notes:                                      6–12...
  • Page 121: Appendix A. Fast

    Appendix A. FAST FAST Overview The CDM‐800 Gateway Router incorporates a number of optional features. In order to permit a  lower initial cost, the unit may be purchased with only the desired features enabled.    If,  at  a  later  date,  the  user  wishes  to  upgrade  the  functionality  of  a  unit,  Comtech  EF  Data  provides Fully Accessible System Topology (FAST), which permits the purchase and installation  of  options  through  special  authorization  codes.  These  unique  Fast  Access  Codes  may  be  purchased from Comtech EF Data during normal business hours, and then loaded into the unit  using the Web Server Interface (accessible via the CDM‐800 rear panel ‘FE’ port).  ...
  • Page 122: Fast Activation Via The Web Server Interface

    CDM-800 Gateway Router Revision 1 Appendix A MN-CDM800 FAST Activation via the Web Server Interface Refer  to  Sect.  5.4.4.2.3  Admin  |  FAST  for  the  complete  information  on  using  the    CDM‐800 Web Server Interface to activate FAST Features.                   ...
  • Page 123: Appendix B. Fec (Forward Error Correction

    Appendix B. FEC (FORWARD ERROR CORRECTION) Introduction The method of FEC (Forward Error Correction) used by the CDM‐800 Gateway Router is based  upon the DVB‐S2 standard for QPSK, 8PSK, 16APSK and 32APSK with concatenated Low Density  Parity Code (LDPC) and Bose‐Chaudhuri‐Hocquenghem (BCH).  DVB-S2: LDPC and BCH The DVB‐S2 specification has defined a new generation of performance that boosts throughput  by  about  30%  over  DVB‐S  using  the  same  amount  of  bandwidth.  This  new  type  of  coding  and  modulation far exceeds the capability of concatenated Viterbi and Reed Solomon coding.     LDPC  and  BCH  is  also  a  concatenated  error  correction  technique.  LDPC  is  a  very  powerful  coding  scheme with significant, Near‐Shannon Bound Performance. In some cases, as the carrier‐to‐noise ...
  • Page 124: Error Performance Characteristics

    * Taken at the -10 dB points on the plot of power spectral density, the occupied bandwidth is 1.19 x Symbol Rate for 35%, and 1.15 x Symbol Rate for 25%. CDM-800 Error Performance Characteristics On  the  pages  that  follow,  Figure  B‐1  through  Figure  B‐4  illustrate  the  guaranteed  error ...
  • Page 125: Cdm-800 Gateway Router Revision

    CDM-800 Gateway Router Revision 1 Appendix B MN-CDM800 Figure B-1. DVB-S2 QPSK Packet Error Rate versus Es/No     B–3...
  • Page 126 CDM-800 Gateway Router Revision 1 Appendix B MN-CDM800 Figure B-2. DVB-S2 8PSK Packet Error Rate versus Es/No     B–4...
  • Page 127 CDM-800 Gateway Router Revision 1 Appendix B MN-CDM800 Figure B-3. DVB-S2 16APSK Packet Error Rate versus Es/No     B–5...
  • Page 128 CDM-800 Gateway Router Revision 1 Appendix B MN-CDM800 Figure B-4. DVB-S2 32APSK Packet Error Rate versus Es/No  B–6...
  • Page 129 METRIC CONVERSIONS Units of Length Unit Millimeter Centimeter Inch Foot Yard Meter Kilometer Mile 1 millimeter 0.0394 0.0033 0.0011 0.001 1 x 10 6.214 x 10 1 centimeter 0.3937 0.0328 0.0109 0.01 1 x 10 6.214 x 10 1 inch 25.4 2.54 0.0833...
  • Page 130 2114 85281 WEST TH STREET TEMPE ARIZONA 480 • 333 • 2200 PHONE 480 • 333 • 2161...

Table of Contents