Procedure In Case Of Power Failure; Technical Data; Instructions For Installation And Limitations Of Use - Wega Espresso Coffee Machine Use And Maintenance Manual

Espresso coffee machine
Hide thumbs Also See for Espresso Coffee Machine:
Table of Contents

Advertisement

R

10. PROCEDURE IN CASE OF POWER FAILURE

If there is a power outage, the system will store all data concerning the count of servings delivered.
Since the update of the count takes place at the start of the delivery of the serving, if it is aborted due to a power outage, it is still counted
and recognized by the dosing device. In this case, delivery is not performed and the serving is not counted.

11. TECHNICAL DATA

GENERAL DATA
• Power supply voltage
• Operating temperature
• Operating humidity
• Transformer
• Input - keys
• Signals for serial transmission
CONNECTIONS for "PANEL" model
• Power supply
• Analogue inputs
• Digital inputs
• High voltage outputs
• Serial connection
CONNECTIONS for "COUNTERTOP" model
• Power supply
• Digital inputs
• Serial connection

12. INSTRUCTIONS FOR INSTALLATION AND LIMITATIONS OF USE

WIRING
Wiring of the cards must be laid out in consideration of the need to separate low voltage from high voltage connections.
The length of any cable must be as short as possible to allow correct connection.
If necessary, screened cables must be used.
The unit must also be located far from devices which may create electromagnetic disturbances when in operation, such as pumps, solenoid
valves, remote switches, motors in general, and neon lights.
SURROUNDINGS
The unit must be placed as far as possible from potential heat sources and excessive humidity and from places where, for any reason, con-
densation may form.
SOILING
Inside the machine, the card must be suitably protected against soiling.
By definition, "in general, the inside of a unit having a case which sufficiently protects it from dust is considered to be protected against soiling"
(EN 60335-1).
CNS 10
English
espresso coffee machine - servings count
200-230Vac or 100-115Vac
10-55°C
30-85 % RH without condensation
2 VA - clim.categ. T70/E - 4 KVca
Switch / Pure contact
RS232 0-5V
FAST - ON
Included for AMPMODU2
AMPMODU2
Included for FAST-ON
AMPMODU2
Bi-polar plug
Cable with activation keys inside the case
5-way circular connection