Advertisement

 
 
CP1350EAVRLCD/CP1500EAVRLCD
User's Manual
 
K01-0000076-00

Advertisement

Table of Contents
loading

Summary of Contents for CyberPower CP1350EAVRLCD

  • Page 1     CP1350EAVRLCD/CP1500EAVRLCD User’s Manual   K01-0000076-00...
  • Page 2: Important Safety Instructions

    1.Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral equipment does not exceed 1350 VA/ 1500VA. 2.Ensure that the equipment plugged into the battery power-supplied/surge outlets does not exceed the UPS unit's rated capacity (1350VA/810W for CP1350EAVRLCD, 1500VA 2 ...
  • Page 3: Basic Operation

    /900W for CP1500EAVRLCD). If the rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down and the circuit breaker to trip. 3.If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert Watts (W) or Amps (A) into VA by performing the calculations below.
  • Page 4: Hardware Installation Guide

    This heat creates energy dissipation resulting in a "Power Loss" or consumption of utility power and money. CyberPower's GreenPower Circuit Design is a solution to this "Power Loss. " When the Utility Power is operating normally, our Green Power UPS works in Bypass Mode.
  • Page 5: Battery Replacement Procedure

    On average utility power operates 88% of the time and the CyberPower GreenPower Technology will work in its money/energy saving Bypass Mode. BATTERY REPLACMENT CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of personnel knowledgeable of batteries and their precautions.
  • Page 6: Definitions For Illuminated Lcd Indicators

    To clear the overload, unplug some of your equipment from the battery-supplied outlets until the icon turns off and the alarm stops. FAULT icon: This icon appears if there is a problem with the UPS. Contact CyberPower Systems at service@cyberpower-eu.com for further help and support.
  • Page 7: Technical Specifications

    TECHNICAL SPECIFICATIONS Model CP1350EAVRLCD CP1500EAVRLCD Capacity (VA) 1350VA/810W 1500VA/900W Input Input Voltage Range 165VAC~265VAC Frequency Range 50/60Hz (Auto Sensing) AVR Function Boost @ 200+/-10V Output On Battery Output 230Vac +/-10% Voltage On Battery Output 50/60Hz +/-1% Frequency Transfer Time 8ms Typical...
  • Page 8: Troubleshooting

    Flight Forum 3545 5657DW Eindhoven The Netherlands Tel: +31 40 2348170, E-MAIL: sales@cyberpower-eu.com Entire contents copyright ©2004 CyberPower Systems B.V., All rights reserved. Reproduction in whole or in part without permission is prohibited. PowerPanel® and PowerPanel® Plus are trademarks of CyberPower Systems (USA) Inc.