Technical Data - Potterton Performa System 12 HE Installation & Service Instructions Manual

Wall mounted powered flue condensing combination boiler gas fired central heating unit
Hide thumbs Also See for Performa System 12 HE:
Table of Contents

Advertisement

Appliance Type
Appliance Category
Heat Input
Max
kW
12.6
Heat Output (Non-Condensing)
Max
kW
12
Heat Output (Condensing)
Max
kW
12.5
Max Gas Rate (Natural Gas - G20)
(After 10 Mins)
m
3
/h
1.33
Burner Pressure (Natural Gas - G20)
Max Rate
mbar
5.7 ± 0.5
Inlet Pressure (Natural Gas - G20)
mbar
20
Burner Injector (Natural Gas - G20)
10 x 1.18mm Diameter
Electrical Supply
(Appliance must be connected to an
earthed supply)
Power Consumption
External Fuse Rating
Internal Fuse Rating
Fuse 2A Fast Blow to BS 4265
Electrical Protection
IPX5D
SEDBUK Declaration For Performa System 12 HE
The seasonal efficiency (SEDBUK) is 86.8% (88.9% LPG)
This value is used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by 0051.
LPG Propane - G31
Burner Injector 0.69mm diameter
Burner Pressure
Propane
mbar
Inlet Pressure
mbar
8
C
C
NO x Class
12
32
CAT II
2H 3P
Condensate Drain
Flue Terminal
Min
Dimensions
7
Connections
Gas Supply
Central Heating Flow
Min
Central Heating Return
6.5
Pressure Relief Discharge -
Outercase Dimensions
Min
Casing Height
6.7
Overall Height Inc Flue
Elbow
Casing Width
Casing Depth
Clearances
Above Casing
Min Rate
Below Casing
1.9 ± 0.5
Front
Front
L.H. Side
R.H. Side
*NOTE: The boiler can be operated with a
clearance of 5mm at the right. This is also
230V~ 50H z
sufficient for routine maintenance.
However a clearance of 20mm is required
if it is necessary to remove the secondary
heat exchanger. This should be
140W
considered when siting the appliance and
in the event of any subsequent alterations
3A
in the area of installation
Weights
Packaged Boiler Carton
Installation Lift Weight
Band B
Max Rate
Min Rate
23.4 ± 0.5
7.4 ± 0.2
37
4.0

TECHNICAL DATA

4.1
System 12 HE
3
1" BSP
Diameter
100mm
Projection
125mm
copper tails
-
22mm
-
22mm
-
22mm
15mm
-
780mm
-
965mm
-
450mm
-
345mm
200 mm Min
200 mm Min
450 mm Min (For Servicing)
5 mm Min (In Operation)
5mm Min
5mm Min (In Operation)
20mm Min (See Note*)
kg
48.5
38
Pump - Available Head
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
0
200
400
Central Heating Primary Circuit
Pressures
Safety Discharge
Max Operating
Min Operating
Recommend Operating
Pump
Available Head
See graph below
Expansion Vessel - (For Central Heating
only. Integral with appliance)
Min Pre-charge Pressure
Max Capacity of
CH System
Primary Water Content
of Boiler (unpressurised)
Temperatures
Flow Temp
(adjustable)
35°C to 85°C
max
600
800
1000
Flow Rate (l/h)
Publication No. 5111817
bar
3
2.5
0.5
1-2
bar
0.5
litre
125
1.2
(± 5°C)
1200