Water inlet fault
Problem
The In-operation
indicator is flashing
quickly.
The buzzer is sounding.
One of the following
faults is shown in the
display:
Open stopcock
Water intake
The following message
appears in the display
during the
SolarSave
programme:
Intake temp. low
68
Cause and remedy
The stopcock is closed.
Open the stopcock fully.
Before rectifying the problem:
Switch the dishwasher off with the button.
The water intake is restricted.
Open the stopcock fully and start the programme
again.
Clean the water inlet filter (see "Maintenance").
The water pressure at the intake is lower than 30
kPa (0.3 bar).
Seek professional advice.
The intake water has not reached the required
temperature of 45°C (see "Plumbing, Connection to
the water supply").
Start the programme again.
If the fault message appears again, select a