Hunter Argenus 30987 Owner's Manual

Hunter Argenus 30987 Owner's Manual

Air sterilizer

Advertisement

Models 30580, 30581, & 30582
Replacement Filter Information
Models
Main Filter
30580, 30581, 30582
30987
www.hunterfan.com
43006-01 20080819
© 2008 Hunter Fan Company

Advertisement

Table of Contents
loading

Summary of Contents for Hunter Argenus 30987

  • Page 1 Models 30580, 30581, & 30582 Replacement Filter Information Models Main Filter 30580, 30581, 30582 30987 www.hunterfan.com 43006-01 20080819 © 2008 Hunter Fan Company...
  • Page 2: Table Of Contents

    Table of Contents Introduction ... 2 Safety Instructions ... 3 Description of Air Sterilization System How the Air Sterilizer Works ... 4 Air Sterilizer Components ... 4 Controls and Indicators ... 5 Operation Initial operation ... 6 Air Sterilizer Maintenance Cleaning Your Air Sterilizer ...
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS Air Sterilizer. WARNING - RISK OF ELECTRIC SHOCK To reduce the risk of electric shock, do not per form any servicing other than that contained in these operating instructions unless you are qualified to do so. This equipment should be inspected frequently and collected dir t removed from it regularly to prevent excessive accumulation that could result in flashover or risk of fire.
  • Page 4: Description Of Air Sterilization System

    Description of Air Sterilization System How the Air Sterilizer Works Dust & Irritants Dirty Air In Fig. 1 - Illustration of the Air Sterilization System Air Sterilizer Components Main Filter Back Fig. 2 - Air Sterilizer Components pollen & Germs & Allergens Bacteria pre-Filter...
  • Page 5: Controls And Indicators

    Description of Air Sterilization System Controls and Indicators power Indicator Medium High Fan Speed Control Dial Fault Indicator Fig. 2 - Air Sterilizer Controls and Indicators 43006-01 Main Filter Reset Button Fan Speed Control Dial (Top Cover Removed) pre-Filter Reset Button...
  • Page 6: Operation

    operation Initial operation NOTE: The power cord has a three-prong grounded plug, and must be used with an electrical outlet that can accommodate the grounding pin. DO NOT use an adaptor if your power outlet can not accommodate the three-prong grounded plug.
  • Page 7: Filter Life Counters

    Filter Life Counters When the Pre-Filter Life Counter exceeds 1400 hours, the Pre-Filter Indicator will flash amber as a reminder that you should clean the pre-Filter. When the Main Filter Life Coun- ter exceeds 8000 hours, the Main Filter Indicator will flash amber as a reminder that you should change the Main Filter. pre-Filter Indicator (Amber, flashing) Fig. 3 - Pre-Filter and Main Filter Indicators, Top Cover On Cleaning the pre-Filter and Changing the Main Filter To access the pre-Filter and the Main Filter: 1.
  • Page 8 Air Sterilizer Maintenance Cleaning the pre-Filter and Changing the Main Filter (cont.) NOTES: • The Air Sterilizer must be unplugged during the cleaning process. • The Pre-Filter will fit into the unit ONLY when oriented correctly. If the Pre-Filter does not slide easily into the unit, do not force it. Simply turn the Pre-Filter around, and reinsert it into the unit. • The Air Sterilizer will not operate if the Pre-Filter is either out of the unit, or is not seated correctly in the unit.
  • Page 9 Cleaning the pre-Filter and Changing the Main Filter (cont.) NOTES: • The Air Sterilizer must be unplugged during the cleaning process. • The Main Filter will fit into the unit ONLY when positioned correctly. The Main Filter has ridges that fit into grooves in the Base. • The Air Sterilizer will not operate if the Main Filter is either out of the unit, or is not seated correctly in the unit. To change the Main Filter and reset the Main Filter Life Counter: 1. Remove the used Main Filter. See Figure 7. Throw away the used Main Fil- ter.
  • Page 10 Air Sterilizer Maintenance Cleaning the pre-Filter and Changing the Main Filter (cont.) 3. Reset the Main Filter Life Counter by pressing the Main Filter Reset Button. See Figure 9. Fan Speed Control Dial (Top Cover Removed) Fig. 9 - Resetting the Main Filter Life Counter NOTES: • Make certain the Pre-Filter, the Main Filter, and the Top Cover are installed cor- rectly.
  • Page 11 Cleaning the pre-Filter and Changing the Main Filter, pg. 7) 3. plug the unit in, and turn it on. 4. If the Fault Indicator is still on, contact Hunter Fan Technical Support at 830-1326, or contact us over the internet at www.hunterfan.com.
  • Page 12: Troubleshooting

    Troubleshooting Problem 1. Unit does not operate. 2. Unusual noise; pop- ping, sizzling, etc. 3. Pre-Filter and/or Main Filter indicator is on. 4. Unit has reduced air flow or increased noise. 5. Fault Indicator is on. Obtaining Replacement Main Filters To obtain replacement Main Filters for your Air Sterilizer, first determine your model number by looking at the information label on the back of the Air Sterilizer.
  • Page 13: Warranty Information

    Hunter Fan Company Air Sterilizer 5 YEAR LIMITED WARRANTY The Hunter Fan Company makes the following limited warranty to the original residential user or consumer purchaser of the Air Sterilizer: If any part of your Air Sterilizer motor or control panel fails during the first five (5) years from the date of installation due to a defect in material or workmanship, we will provide a replacement Air Sterilizer free of charge.
  • Page 14 Warranty To obtain service, contact the Hunter Fan Company Service Department, 2500 Frisco Avenue, Memphis, Tennessee 38114, 1-888-830-1326. You will be responsible for insurance and freight or other transportation to our factory service center. We will return the Air Sterilizer freight prepaid. The Air Sterilizer should be properly packaged to avoid damage in transit since we will not be responsible for any such damage.
  • Page 15 HUNTER FAN CoMpANY ® 2500 FRISCo AVENUE MEMpHIS, TN 38114, USA Printed in China and Taiwan 43006-01...
  • Page 16 43006-01...

This manual is also suitable for:

Argenus 30580Argenus 30581Argenus 30582

Table of Contents