5.2 Triax diagnostic indications

The Camera TEST LED lights red during these fault conditions.
General precautions to avoid Triax problems
Only use Triax cable (with three conductors).
Ensure that all Triax connectors (camera, base station and extension cables) fit snugly into
each other.
Verify that there is no interruption in all three conductors of the Triax cable before
deploying (including extension Triax cables).
When using Triax connectors be sure to always make swift and firm connections to avoid
unintended fault conditions.
Verify that there is no shortcircuit between the outer and inner shield or core.

5.2.1 Core Open

Figure 5-2. Fault conditions for Core_Open message
1. Indicates an interrupted core when both shields are connected correctly while the
camera is connected.
2. Indicates a short circuit between the outer and inner shield while the camera is
NOT connected.
Base Station diagnostic message: DIAGNOSTICS/BOARD DIAGNOSTICS/POWER BOARD/
TRIAX STATUS >> COPEN
LDK 4502/4503/4506 HDTV camera base station User's Guide (v3.5)
Connected
Connected
Interrupted
Chapter 5 - Diagnostics