5.2 Triax diagnostic indications
The Camera TEST LED lights red during these fault conditions.
General precautions to avoid Triax problems
•
Only use Triax cable (with three conductors).
•
Ensure that all Triax connectors (camera, base station and extension cables) fit snugly into
each other.
•
Verify that there is no interruption in all three conductors of the Triax cable before
deploying (including extension Triax cables).
•
When using Triax connectors be sure to always make swift and firm connections to avoid
unintended fault conditions.
•
Verify that there is no shortcircuit between the outer and inner shield or core.
5.2.1 Core Open
Figure 5-2. Fault conditions for Core_Open message
1. Indicates an interrupted core when both shields are connected correctly while the
camera is connected.
2. Indicates a short circuit between the outer and inner shield while the camera is
NOT connected.
Base Station diagnostic message: DIAGNOSTICS/BOARD DIAGNOSTICS/POWER BOARD/
TRIAX STATUS >> COPEN
LDK 4502/4503/4506 HDTV camera base station User's Guide (v3.5)
Connected
Connected
Interrupted
Chapter 5 - Diagnostics
55