For products without a plug

This appliance must be connected by a
competent person, using fixed wiring via
a double pole switched fused spur outlet,
with a contact separation of 3mm at all
poles.
Use a 13 amp fuse.
We recommend that the appliance is
connected by a qualified electrician,
who will comply with the I.E.E. and local
regulations.
Warning: This appliance must be earthed.
The wires in the mains lead are coloured
in accordance with the following code:
Green & Yellow = earth, Blue = neutral,
Brown = live.
Typical example of a double pole
fuse spur outlet
INSTALLATION
As the colours of the wires in the mains
lead for the appliance may not cor-
respond with the coloured markings
identifying the terminals in your spur box,
proceed as follows:
1. The wire which is coloured green and
yellow must be connected to the
terminal marked E (Earth) or coloured
green.
2. The wire which is coloured blue must
be connected to the terminal marked
N (Neutral) LOAD or coloured Black.
3. The wire which is coloured brown must
be connected to the terminal marked L
(Live) LOAD or coloured Red.
If the supply cord is damaged, obtain a
special cord from the Customer Support
Helpline, which must be fitted by a
qualified person.