To Service the Boiler & Component Replacement - Page 29
4.3.8 Fan & Flue Hood
Gain General Access - See 4.1
1. Disconnect the tube from the front of the fan
housing - note how it fits.
2. Disconnect the three wires from the fan motor.
3. Remove the two screws securing the fan to the
flue hood.
4. Carefully pull the fan down and away from the
boiler.
5. Flue Hood: On re-assembly ensure that the flue
hood locates under the two brackets at the rear of
the chassis. Check the seal and replace if
damaged.
6. Fan: On re-assembly ensure that the rubber seal
around the fan opening is located correctly into
the base of the flue elbow.
7. Re-assemble in reverse order.