Wiring - Empire DV-20E-5 Installation Instructions And Owner's Manual

Fan type direct vent wall furnace
Table of Contents

Advertisement

OPTIONAL WALL MOUNT THERMOSTAT
DISCONNECT INTEGRAL THERMOSTAT "R", "W", AND "C" LEADS AND ATTACH WALL THERMOSTAT AS SHOWN
W
R
THERMOSTAT
ELECTRONIC
INTEGRAL
The appliance, when installed, must be electrically grounded in ac-
cordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code,
CSA C22.1, if an external electrical source is utilized. This appli-
ance is equipped with a three-prong [grounding] plug for your
protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug. For an ungrounded
receptacle, an adapter, which has two prongs and a wire for ground-
ing, can be purchased, plugged into the ungrounded receptacle and
its wire connected to the receptacle mounting screw. With this wire
completing the ground, the appliance cord plug can be plugged into
the adapter and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Note: For testing flame sensor circuit use a micro-amp meter in
series with sensor. Minimum current should be 1 micro-amp dur-
ing operation. Be careful as flame sensor is in the 115VAC circuit.
If current is below 1 micro-amp, remove sensor, clean with light
sandpaper and retest.
Note: This heater is equipped with a remote bulb electronic thermistor
control located down low at the back of the furnace. Sometimes due
Page 14
XFMR
GV
ORG
ORG
GRN
9
6
3
RED
8
5
2
7
4
1
RED
BLU
BLU
6
3
5
2
4
1
PUR
PUR
WHT
BLK
CIRCULATING AIR BLOWER

WIRING

ON/OFF
POWER SWITCH
RED LED
STATUS
LIGHT
HOT SURFACE
IGN
GND
3A FUSE
WHITE
BLACK
ON/OFF
THERMOSTAT
INDUCER
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
BLOWER
APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED
WITH A WIRE OF AT LEAST 105
to field locations different air currents may effect the control sensing
of the thermistor. This sensing bulb can be re-located if necessary to
provided for better room air sensing and control.
Replacement of Thermistor with 24 Volt Wall Thermostat
1. If furnace is installed, turn off gas supply and electric supply.
2. Remove casing front.
3. Remove black hose from front nipple on pressure switch.
4. Remove junction box cover (4 screws).
5. Please refer to wiring diagram for removal of the following
wires.
6. Internal Electronic Thermostat/Temperature Control
Board
Attention! No 24 volt wall thermostat wires are to be at-
tached to the internal electronic thermostat.
7. Control Board
A. Remove white wire form screw marked W.
B. Remove yellow wire from screw marked C.
C. Remove red wire from screw marked R.
8. Route (2) wires from any 24 volt wall thermostat through the
casing back of furnace to the screws marked W and R on the
control board.
9. Replace junction box cover (4 screws).
10. Replace black hose onto front nipple on pressure switch.
11. Replacement of thermistor with 24 volt wall thermostat is
completed.
GV = GAS VALVE
LS = LIMIT SWITCH
FS = FLAME SENSOR
XFMR = TRANSFORMER
PS = PRESSURE SWITCH
IGN = HOT SURFACE IGNITOR
ROS = ROLLOUT LIMIT SWITCH
CORDSET 115 VAC
BLACK HOT
BLACK NEUTRAL
SMOOTH
RIBBED
INSULATION
INSULATION
CIRCULATING AIR
BLOWER MOTOR
COMBUSTION AIR
INDUCER MOTOR
IGNITOR
FLAME SENSOR
PRIMARY
115 VAC
TRANSFORMER
SECONDARY
24 VAC
LIMIT
ROLLOUT
PRESSURE
SWITCH
LIMIT SWITCH
SWITCH
115 VAC
24 VOLT
FIELD INSTALLED
° C TEMPERATURE RATING.
COMMON
GAS
VALVE
R-8191
19562-5-1012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dv-40e-5

Table of Contents