Empire DV-25-2SG Installation Instructions And Owner's Manual

Direct vent wall furnace

Advertisement

Quick Links

WARNING: If the information in
this manual is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
R-2070
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
AND
DIRECT VENT
WALL FURNACE
MODELS
DV-25-2SG
DV-35-2SG
EFFECTIVE DATE
NOVEMBER, 2000
This appliance may be installed in an
aftermarket permanently located, manu-
factured (mobile) home, where not pro-
hibited by state or local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certified kit is
used.
WARNING: If not installed, operated and
maintained in accordance with the
manufacturer's instructions, this product
could expose you to substances in fuel or
from fuel combustion which can cause
death or serious illness.
Page 1

Advertisement

loading

Summary of Contents for Empire DV-25-2SG

  • Page 1 INSTALLATION INSTRUCTIONS OWNER'S MANUAL DIRECT VENT WALL FURNACE MODELS DV-25-2SG DV-35-2SG WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or EFFECTIVE DATE loss of life. NOVEMBER, 2000 —...
  • Page 2 Introduction Installation in Residential Garages Always consult your local Building Department regarding regulations, Gas utilization equipment in residential garages shall be installed so codes or ordinances which apply to the installation of a direct vent wall that all burners and burner ignition devices are located not less than 18" furnace.
  • Page 3 SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday when there may not be a minute to lose, everyone's safety will and explosions. In its natural state, propane is odorless and colorless.
  • Page 4 Location of Furnace INCHES (mm) Pick a location on an outside wall with a clear space of 28" (711mm) high by 49" (124cm) wide in the room. 4 1/2 (114) MIN. WALL DV-25, DV-35 13 (330) MAX. WALL DV-25, DV-35 (DV-25-2 SHOWN) Clearances 1.
  • Page 5 DV-35. (See Figure 3) 6" (152mm) diameter air inlet tube. Position the outside mounting Vinyl siding vent kit, DV-822, is available from Empire Comfort plate so that 6" (152mm) diameter air inlet tube has a slight Systems, Inc. The depth is 3" (76mm), which enables the vent cap downward slope to the outside.
  • Page 6 Gas Supply Checking Manifold Pressure Check all local codes for requirements, especially for the size and type Both Propane and Natural gas valves have a built-in pressure regulator in of gas supply line required. On Natural gas lines less than 15' (4.58m) the gas valve.
  • Page 7 Removing Main Burner 1. Disconnect the thermopile and pilot supply line at the pilot burner. BURNER FLAME 2. Remove the burner compartment cover. 3. Remove orifice shield. 4. Remove bolt on each side of burner and lift out. Cleaning Main Burner The main burner may be cleaned by forcing water into the ports and the throat of the burner.
  • Page 8: For Your Safety Read Before Lighting

    FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by •...
  • Page 9: Service And Maintenance Suggestions

    SERVICE AND MAINTENANCE SUGGESTIONS CALL SERVICEMAN SYMPTOMS -POSSIBLE CAUSES AND CORRECTIONS 1. Lit match goes out as it enters lighter port. e. Cover on pilot lighter hole must be air tight. a. Certain wind conditions will blow out match. Ignite match, f.
  • Page 10 How To Order Repair Parts... Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list.
  • Page 11 OPTIONAL BLOWER DRB-1 Vented Room Heaters RH-25-(1, 2, 4) and RH-35-(1, 2, 4) Direct Vent Wall Furnaces DV-25-(1, 2)SG and DV-35-(1, 2)SG Installing Optional DRB-1 Blower Fan Control 1. For RH-25-(1, 2, 4) and RH-35-(1, 2, 4), remove casing front. The automatic fan control is located in the switch box.
  • Page 12 Cleaning The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel. Complete removal of the wheel and scrubbing it with a brush under flowing water is recommended. Oiling The blower motor has an oil hole located on each end of the motor.