Escape 1800 Insert Installation and Operation Manual
CLEARANCES
16" (406 mm)
F
12" (305 mm)
G
20" (508 mm)
H
22" (559 mm)*
I
12" (305 mm)
O
1" (25 mm)
P
B
M
N
Minimum floor to ceiling clearance: 84'' (213 cm)
*
For a 8" (203 mm) mantel shelf. See Section 8.3 Compliance of a Combustible
Mantel Shelf for other mantel shelf dimensions. Note that you can reduce the
combustible mantel shelf clearance with the use of a Heat Shield, sold separately. See
Appendix 4: Top Surround and Shelf Heat Shield Installation (AC01317) for detail.
** Where a fresh air intake is needed, we suggest you add a minimum of 4'' to the width
of the minimum masonry opening.
Note 1: From door opening. The depth of the hearth extension in front of the insert is
included in the calculation of the floor protector's dimensions. The masonry hearth should
be at least 4 inches (102 mm) higher than the combustible floor in front of it. If the hearth
elevation is lower than 4 inches, the non-combustible (B) floor protector in front of the
insert should have an R value equal or greater than 2.00 and shall extend 29 inches (737
mm) in front of the unit.
FLOOR PROTECTION
CANADA
18'' (457 mm) – Note1
8'' (203 mm)
N/A (USA only)
MINIMUM MASONRY
OPENING
24 3/8" (619 mm)
J
30 3/8" (772 mm)**
K
17 1/4" (438 mm)
L
USA
16'' (406 mm) – Note 1
N/A (Canada only)
8'' (203 mm)