CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)
16
WARNING
!
• Conversion must be made by a qualified technician.
• Changing orifices and gas valve adjustments improperly can result in an explosion and/or fire.
Note
The dryer is shipped from the factory set up and adjusted to operate on natural gas. It can be converted to operate on
propane (LPG). The conversion kit may be sold only to a licensed gasfitter, and must be performed ONLY by a licensed
gasfitter. This is not a do-it-yourself.
STEP 1 : VALVE SETTING
Opened
Full open
Adjustment screw
STEP 2 : ORIFICE CHANGE
Orifice
Closed
Close
Adjustment screw
① Remove 2 screws.
② Disassemble the pipe assembly.
③ Replace natural gas orifice with propane gas orifice.
Gas type
Orifice P/No
Natural Gas
4948EL4001B
Propane Gas
4948EL4002B
※ Kit contents: Orifice (Dia. = 1.613mm, for Propane Gas)
Replace Label
Instruction Sheet
47
Marking
Shape
NCU
PCU