Optimizing the 10-GbE Port Configuration

The 10-GbE ports on the ProCurve Switch 3500yl and 6200yl series are
designed to deliver full 10 Gbps wire-speed to each port, where either one or
two ports are in a linked state with another device. When three or four 10-GbE
ports are in a linked state, the 10-GbE ports support an aggregate bandwidth
of 28.8 Gbps across the linked ports.
As illustrated in the figure below, internally, there are two 14.4-Gbps channels
between each of the 4 10-GbE ports and the switch fabric.
Figure 2-25. 10-GbE port architecture showing ports grouped by 14.4 Gbps channel.
SG12345678
ProCur ve Switc h yl
10-GbE X2 Port
X2/CX4 10-GbE Module
1
J8694A
Mdl S tatus
10-GbE CX4 P orts
2
Link
1
2
3
Activity
y l
SG12345678
ProCur ve Switc h yl
10-GbE X2 Port
X2/CX4 10-GbE Module
1
J8694A
Mdl S tatus
10-GbE CX4 P orts
2
Link
1
2
3
Activity
y l
SG12345678
ProCur ve Switc h yl
10-GbE X2 Port
X2/CX4 10-GbE Module
1
J8694A
Mdl S tatus
10-GbE CX4 P orts
2
Link
1
2
3
Activity
y l
A1
A4
A2
1
4
2
(X2)
(X2)
(CX4)
14.4 Gbps
14.4 Gbps
14.4 Gbps
14.4 Gbps
Channel
Channel
Channel
Channel
10 - GbE Module Ports
10-GbE Ports
Switch
CAUTION: MUL TIPLE PO WER SOUR CES
Disconnect all AC po wer cords, and EPS and RPS
10-GbE X2 Port
cables to complet ely remove po wer from the unit.
4
12V Sys tem Power (RPS) Input
3
4
CAUTION: MUL TIPLE PO WER SOUR CES
Disconnect all AC po wer cords, and EPS and RPS
10-GbE X2 Port
cables to complet ely remove po wer from the unit.
4
12V Sys tem Power (RPS) Input
3
4
CAUTION: MUL TIPLE PO WER SOUR CES
Disconnect all AC po wer cords, and EPS and RPS
10-GbE X2 Port
cables to complet ely remove po wer from the unit.
4
12V Sys tem Power (RPS) Input
3
4
A3
3
(CX4)
Installing the Switch
Sample Network Topologies
P oE
50V P oE (EPS) Input
Line: 50/60 Hz.
100-127 V~ 1 0 A
Connect ProCur v e 620 EPS only
200-240 V~ 5 A
P oE
50V P oE (EPS) Input
Line: 50/60 Hz.
100-127 V~ 1 0 A
Connect ProCur v e 620 EPS only
200-240 V~ 5 A
P oE
50V P oE (EPS) Input
Line: 50/60 Hz.
100-127 V~ 1 0 A
Connect ProCur v e 620 EPS only
200-240 V~ 5 A