Vermont Castings 1920 Homeowner's Installation And Operating Manual page 7

The aspen woodburning stove
Table of Contents

Advertisement

Chimney Connector
Heat Shield
*
Note clearance
requirement on
pages 13-14
fig. 5 If the clearance between the chimney connector and
either the ceiling or the mantel is inadequate, a protective
heat shield is required.
ST244
Plymouth
fplc over mantel
*
maintain required clearance.
12/99
See page 13.
Flex Connector
*
*
406 mm
(16")
fig. 7 Special adapter kits are available from your local
dealer to simplify fireplace installations.
30003844
*
*
Mantel
Min. 381 mm
(15")
Fireplace
Adapter w/
Clean-out Tee
ST245
fireplace
flex connector
12/99
Whenever possible, design the installation so that the
connector does not pass through a combustible wall.
If you must include a wall pass-through in your instal-
lation, check with your building inspector before you
begin. Also check with the chimney connector manu-
facturer for any specific requirements.
Consult with your dealer regarding special connection
components available for use as wall pass-throughs.
Use only parts that have been tested and listed for use
as a wall pass-through.
Figure 7 shows one approved method of passing a
connector through a wall. All combustible material in the
wall is cut away to provide the required 457 mm (18")
clearance around the connector. The resulting space
must remain empty. A flush-mounted sheet metal cover
may be used on one side only. If covers must be used
ST44
on both sides, each cover must be mounted on non-
combustible spacers at least 5 mm (1") clear of the
wall. Your local dealer or your local building inspector
can provide details of other approved methods of pass-
ing a chimney connector through a combustible wall.
Min. 460 mm
(18")
ST76
fig. 7 CSA approved Wall Pass-through.
ST45
Aspen
Woodburning Stove
®
wall pass-throughs
Chimney clearance to sheet steel
supports and combustibles
4 ga. Sheet
Steel Support
(one side only)
Masonry Chimney
ST276
CSA approved wall
pass-through
12/99
51 mm (")
Min.
Min. 460 mm
(18")
Chimney
Connector
4 ga.Sheet
Steel Support
7