Mackie Digital 8 Bus Owner's Manual page 120

56-input, 72-channel, fully automated digital audio mixing console
Hide thumbs Also See for Digital 8 Bus:
Table of Contents

Advertisement

Console Settings
1. Set the Tape Input and Tape Output
format for each DIO•8 card to TDIF.
2. If the D8B is the clock master, set the
Sample Rate to either 44.1kHz or
48kHz, and set the Apogee Clock to
Internal (in the Digital I/O Setup
window). If it is a clock slave, set the
Apogee Clock to Word Clock. Set the
Sample Rate to match the Sample
Rate selected on the HDR24/96.
D8B Manual • Chapter 4 • page 114
ADAT Optical Hookup to HDR24/96
(DIO•8 or OPT•8)
Cables & Hardware
(3) DIO•8 or OPT•8 cards for HDR24/96
(3) DIO•8 or OPT•8 cards for D8B
(1) Clock I/O card for D8B
(6) ADAT Optical cables
(1) 75Ω BNC word clock cable
Hookup
1. Connect three ADAT Optical cables
from the HDR24/96 Optical Outputs to
the Optical Inputs on the
corresponding D8B I/O cards.
2. Connect three ADAT Optical cables
from the HDR24/96 Optical Inputs to
the Optical Outputs on the
corresponding D8B I/O cards.
3. When ADAT Optical is used, the D8B
must have a Clock I/O card installed.
To make the D8B the clock master,
connect its Word Clock Out to the
HDR24/96 Word Clock In. To make
the HDR24/96 the clock master,
connect its Word Clock Out to the D8B
Word Clock In.
HDR24/96 Settings
1. If you have DIO•8 cards installed, set
the Tape Input and Tape Output
format for each card to ADAT. OPT•8
cards need no configuration.
2. If the HDR24/96 is the clock master,
set the Sample Clock to Internal. If
the HDR24/96 is a clock slave, set the
Sample Clock to Word Clock and
depress the 75Ω termination button
on the Sync card.
3. Set the Sample Rate to 44.1kHz or
48kHz according to your preference.

Advertisement

Table of Contents
loading

Table of Contents