ATER FILTER DATA
SYSTEM SPECIFICATION AND PERFORMANCE DATA
SHEET REFRIGERATOR WATER FILTER CARTRIDGE
MODEL OWF51
Specifications
Service Flow Rate (maximum) ...............................................0.75 GPM (2.83 L/min)
Rated Service Life OWF50-NI300 (maximum) ......................300 gallons (1135 liters)
Rated Service Life OWF50-WI500 (maximum)......................500 gallons (1892 liters)
Maximum Operating Temperature..........................................100° F (38° C)
Minimum Operating Temperature...........................................33° F (1° C)
Minimum Pressure Requirement............................................35 psi (138 kPa)
Maximum Operating Pressure ...............................................120 psi (827 kPa)

PERFORMANCE DATA

Influent Challenge
Substance
Concentration
Lead
0.15 mg/L +/- 10%
Lead
0.15 mg/L +/- 10%
Cyst
Minimum 50,000/L
Turbidity
11+/-1 NTU
Lindane
0.002 mg/L +/- 10%
Atrazine
0.009 mg/L +/- 10%
Chlorine
2.0 mg/L +/- 10%
Particulate**
at least 10,000
particles/mL
2,4-D
0.210 mg/L +/- 10%
Asbestos
10
7
to 10
8
fibers/L; fibers greater
than 10 micrometers in length
* Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa) under
standard laboratory conditions, however, actual performance may vary. Health Claim Performance test-
ed and certified by NSF International
** Particle size range classification of test. Particles used were 0.5 –1 microns.
(SELECT MODELS)
Effluent
Average %
Maximum
Average
Reduction
Effluent
0.001 mg/L
99.33%
0.001 mg/L
0.002 mg/L
98.66%
0.003 mg/L
1count/mL
99.99%
3 count/mL
0.12 NTU
98.98%
0.18 NTU
0.00005 mg/L
97.62%
0.00005 mg/L
0.0002 mg/L
97.93%
0.0006 mg/L
0.09 mg/L
95.26%
0.17 mg/L
900 count/mL
99.68%
2400 count/mL
45.45 ug/L
84.42%
100 ug/L
0.16 MFL/mL
99.96%
0.16 MFL/mL
1000 Apollo Road
Eagan, Minnesota U.S.A.
EPA EST #35917-MN-1

GENERAL USE

CONDITIONS
Read this Performance Data Sheet and
compare the capabilities of this unit with
your actual water treatment needs.
DO NOT use this product where water
is microbiologically unsafe or of
unknown quality without adequate
disinfection before or after the sys-
tem. System certified for cyst reduc-
tion may be used on disinfected water
that may contain filterable cysts.
Use only with cold water supply.
Check for compliance with the state
Min. Required Inlet
Reduction
pH
and local laws and regulations.
0.010 mg/L
6.5
The retractable water filtration system
0.010 mg/L
8.5
uses a OWF51 replacement cartridge.
> 99.95%
NA
Timely replacement of filter cartridge is
0.5 NTU
NA
essential for performance satisfaction
0.00002 mg/L
NA
from this filtration system. Please refer to
0.003 mg/L
NA
the applicable section in this owner's
≥75%
NA
manual for general operation, mainte-
≥85%
NA
nance requirements and troubleshooting.
Replacement Elements: OWF51
0.0017 mg/L
NA
99%
NA
This system has been tested according to
ANSI/NSF 42 and 53 for reduction of the
substances listed below. The concentra-
tion of the indicated substances in water
entering the system was reduced to a
concentration less than or equal to the
permissible limit for water leaving the sys-
tem, as specified in ANSI/NSF 42 and 53.
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models OWF50-WI500 and OWF50-NI300 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction