Fireplace Installation - Dimplex BF8000ST Practical User's Manual

Electric fireplace
Hide thumbs Also See for BF8000ST:
Table of Contents

Advertisement

Fireplace Installation

Install the fireplace assembly into the mantel. (refer to mantel assembly instructions)
NOTE
A 15 AMP, 120 VOLT circuit is required. A dedicated circuit is preferred but not essential in all
cases. A dedicated circuit will be required if after installation the circuit breaker trips or fuse
blows on a regular basis when the heater is operating. Additional appliances on the same
circuit may exceed the current rating of the circuit breaker.
IMPORTANT
If not using a Dimplex mantel, the fireplace must be installed in an enclosure with the following
MINIMUM dimensions.
New Wall Construction
1. Select a suitable location that is not susceptible to moisture and is away from drapes,
furniture and high traffic.
2. Place the fireplace in the desired location to see how it will look in the room.
3. Mark the desired location on the floor.
4. Use studs to frame an opening of 26.75" wide X 23" high X 9" deep.
Option #1
The power cord can be run from behind the trim and along the wall to an outlet near the
fireplace.
Option #2
A new outlet can be installed inside the framing construction.
Plug the unit into a 15Amp/120Volt outlet. If the cord does not reach, you may use an
extension cord rated for a minimum of 1875 watts.
Existing Fireplace:
1. Seal all drafts and vents with a non-fibrous insulation material to prevent any chimney
debris from falling onto the fireplace. Do not install into an existing fireplace that is
prone to dampness.
2. Cap the top of the chimney flue to prevent rain from entering.
3. Plan your electric power supply.
4. The power cord can run along the front of the hearth to an outlet near the fireplace.
CAUTION
Clearance for air circulation beneath the fireplace insert is provided by two spacers.
DO NOT INSTALL THE FIREPLACE INSERT DIRECTLY ON CARPET OR SIMILAR
SURFACES WHICH MAY RESTRICT AIR CIRCULATION. If installing the fireplace in a
carpeted area, place a one-piece, solid, flat surface under the fireplace insert. Ensure that all
three of the insert's feet rest securely on this surface.
26.75"
9"
23"