Flushing Power Unit - Yamaha F75 Owner's Manual

Outboard motor
Hide thumbs Also See for F75:
Table of Contents

Advertisement

Maintenance
Procedure
1.
Disconnect and remove the battery from
the boat. Always disconnect the black
negative cable first to prevent the risk of
shorting.
2.
Clean the battery casing and terminals.
Fill each cell to the upper level with dis-
tilled water.
3.
Store the battery on a level surface in a
cool, dry, well-ventilated place out of di-
rect sunlight.
4.
Once a month, check the specific gravity
of the electrolyte and recharge as re-
quired to prolong battery life.
EMU28441

Flushing power unit

Perform this procedure right after operation
for the most thorough flushing.
ECM01530
CAUTION:
Do not perform this procedure while the
engine is running. The water pump may be
damaged and severe damage from over-
heating can result.
1.
After shutting off the engine, unscrew the
garden hose connector from the fitting on
the bottom cowling.
45
1. Fitting
2. Garden hose
3. Garden hose connector
2.
Screw the garden hose connector onto a
garden hose which is connected to a
fresh water supply.
3.
With the engine off, turn on the water tap
and let the water flush through the cool-
ing passages for about 15 minutes. Turn
off the water and disconnect the garden
hose.
4.
When flushing is complete, reinstall the
garden hose connector on the fitting on
the bottom cowling. Tighten the connec-
tor securely.
ECM00540
CAUTION:
Do not leave the garden hose connector
loose on the bottom cowling fitting or let
the hose hang free during normal opera-
tion. Water will leak out of the connector
instead of cooling the engine, which can

Advertisement

Table of Contents
loading

This manual is also suitable for:

F90

Table of Contents