CDV7 Series Gas Fireplace
CLEARANCES TO COMbUSTIbLES
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material
other than wood flooring. If installed on carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or noncombustible material panel extending
full width and depth of the appliance.
72"
Minimum
Side
Wall
6"
Minimum
Figure 5 -
Ceiling and Side Wall Clearances
fP2032
wall clearances
ManTel CleaRanCeS
noTe: The combustible area above the facing must not protrude
more than 3/4" from the facing. If it does, it is considered a mantel
and must meet the mantel requirements listed in this manual.
Never obstruct or modify the air inlet or
outlet grilles (louvers). This may create a
fire hazard.
10
12"
Maximum
Depth
13"
Minimum
Top of Heat
Exhaust Vent
FP03
FP86
Side of Fireplace
Opening
Figure 6 -
Mantel Clearances
Finish Wall
12"
8"
13"
6"
7"
2"
5"
3"
Side View
FP2285
mantel clearances
1"
1 "
2 "
3"
5"
6"
Front View
FP2286
Mantel leg clear
CleaRanCeS
Insulation Board
Stud
Header
Standoff
FP85
Stud
Wall
Combustible
Material Area
3 "
4 "
45°