Heatilator Novus Plus Installation & Operating Instructions Manual page 9

Novus plus fresh air fireplace
Table of Contents

Advertisement

NOVUS PLUS INSTALLATION INSTRUCTIONS
b.
Connecting Field-Supplied Wire to Terminal Blocks in Appliance
1)
Disconnect all power.
2)
Strip the end of the low voltage wire to 1/4 in.
3)
Put the blade of a small straight screwdriver in the slot at the top of the appropriate terminal, press down on screwdriver
to open spring clamp and slide the correct low voltage wire into the side of the same slot you are pressing on.
4)
Release pressure from screwdriver to secure wire.
5)
Tug on the wire to make sure of a tight connection in the terminal.
6)
Repeat this procedure for each colored block.
c.
HRV200PLUS Control Wiring
The Novus Plus is designed to operate as a system with the HRV200PLUS. Four low-voltage wires are required to electrically
connect the two appliances. Common 24 gauge solid conductor thermostat wire, or equivalent may be used. The connections
are illustrated in Figure 8.
1)
Defrost Override & Terminal Block
This appliance comes with a defrost override switch and a terminal block. The switch and appliance side of the terminal
block are pre-wired. Four-wire thermostat wire must be run from the appliance to the HRV200PLUS and wired according
to the wiring diagram in Figure 8.
11/04
Figure 8 - Novus Plus & HRV200PLUS Boards Wired Together
4031-478 Rev i
9