Vitotrol 200A; Room Temperature Sensor For Separate Cooling Circuit - Viessmann VITOCAL 300-G Technical Manual

Brine/water and water/water heat pump single and two-stage, from 21 kw
Table of Contents

Advertisement

Heat pump control unit
0
7 2
1 3

Vitotrol 200A

Part no. Z008 341
KM BUS subscriber
A Vitotrol 200A can be used for each heating circuit in a heating sys-
tem. Up to 2 remote controls may be connected to the control unit.
Functions:
■ Display of room temperature, outside temperature and the operating
condition.
■ Setting the standard room temperature (day temperature) and oper-
ating program via the standard display.
4
Note
The reduced room temperature (night temperature) is set at the con-
trol unit.
■ Party and economy mode can be enabled via keys
■ Only for heating circuit with mixer:
Room temperature sensor for room temperature hook-up
Note
For room temperature hook-up, the Vitotrol 200A must be installed
in the living space (lead room).
Installation location:
■ Weather-compensated mode:
Installation at any point in the building.
■ Room temperature hook-up:
Installation in the main living room on an internal wall opposite radi-
ators. Never install inside shelving units, in recesses, or immediately
by a door or heat source (e.g. direct sunlight, fireplace, TV set, etc.).
The integral room temperature sensor captures the actual room
temperature and effects any necessary correction of the flow tem-
perature as well as a rapid heat-up at the start of the heating oper-
ation (if suitably encoded).

Room temperature sensor for separate cooling circuit

Part no. 7408 012
Installation in the room to be cooled on an internal wall, opposite radi-
ators/heat sinks. Never install inside shelving units, in recesses, or
immediately by a door or heat source (e.g. direct sunlight, fireplace,
TV set, etc.).
VIESMANN
66
(cont.)
Specification
Lead length
Setting range
Switching differential
Breaking capacity
Setting scale
DIN reg. no.
Connection:
■ 2-core lead, length max. 50 m (even if connecting several remote
control units)
■ Never route this lead immediately next to 230/400 V cables
■ LV plug as standard delivery
1 4
8
Specification
Power supply via KM BUS
Power consumption
Protection class
IP rating
Permissible ambient temperature
– during operation
– during storage and transport
Set room temperature range
Connect the room temperature sensor to the control unit.
4.2 m, fully wired
30 to 80 °C
max. 14 K
6(1.5) A 250V~
inside the casing
DIN TR 116807
or
DIN TR 96808
0.2 W
III
IP 30 to EN 60529;
ensure through appropri-
ate design/installation
0 to +40 °C
-20 to +65 °C
3 to 37 °C
VITOCAL 300-G