Ipmi - Fujitsu PRIMERGY BX620 S5 Operating Manual

Server blade
Hide thumbs Also See for PRIMERGY BX620 S5:
Table of Contents

Advertisement

BIOS Setup
Baud Rate
Defines the specified baud rate (115.2K, 57.6K, 38.4K, 19.2K, 9600).
I
This item is only hidden if "Port" is set to Disabled.
Protocol
Specifies the transfer protocol (ANSI, VT100, VT-UTF8, VT100+).
I
This item is only hidden if "Port" is set to Disabled.
Flow Control
Specifies how the transfer is controlled via the port. The setting (None,
XON/XOFF) must be the same at both the terminal and server.
I
This item is only hidden if "Port" is set to Disabled.
Continue C.R. after POST
Specifies whether communication with the terminal is also possible whilst
the operating system is being loaded (On) or not (Off).
I
This item is only hidden if "Port" is set to Disabled.
6.8.4

IPMI

SM Error Halt
Specifies the behavior during a system management error or during
configuration changes.
Disabled
A warning message is displayed.
Enabled
Stops and shows Setup entries or a boot prompt.
Load iRMC Default Values
Specifies whether Event Logging is to load the manufacturer's settings
(does not apply to entries that were configured by the BIOS Setup utility).
I
The settings only become effective once you exit the BIOS Setup
by choosing "Save Changes and Exit".
BX620 S5
Operating Manual
Server menu
71