QuickSpecs

Technical Specifications

AiO400t
Dimensions (HxWxD)
Additional
(with feet)
Specifications
Weight
(approximate)
Input Requirements
(per power supply)
Power Specifications
Power Supply Output
(per power supply)
System Inlet Temperature
Relative Humidity
(non-condensing)
Altitude
AiO400R
Dimensions (HxWxD)
Additional
(with bezel)
Specifications
DA - 12913
HP StorageWorks 400t and 400r All-in-One
14.5 x 6.9 x 16.8 in (36.7 x 17.5 x 42.6 cm)
Maximum
39 lb (17.5 kg)
(all hard drives, power
supplies, and processors
installed)
Minimum
23.81 lb (10.8 kg)
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
90 to 132 VAC,
180 to 264 VAC
Rated Input Current
6 A (at 100 VAC),
3 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
600 W (at 100 VAC),
600 W (at 200 VAC)
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator
%20Catalog.xls
- Click on the system of interest. Example: DL380 G5
- Follow the instructions of the next screens.
Rated Steady-State Power
365 W (at 100 VAC),
365 W (at 200 VAC)
Maximum Peak Power
385 W (at 100 VAC),
385 W (at 200 VAC)
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Operating
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)
Worldwide QuickSpecs — Version 1 — 2.11.2008
Storage Systems
Page 19