7.
Electrical
Data
Base level
Voltage
220-230/50
VIV/Hz
Total power
app. 3
kW
Fuses
16
A
Hot water connection up to
60
°C
Timer
Model
Sibel EO P55
Basic step times
1", 15", 30", 120"
Range Band C
= EO 5055 D
Heating
1 Element system:
220 V
2800 W
app. 16,0 Ohm
230 V
3060 W
app. 17,0 Ohm
2 Element system:
(CH + DK )
Element A
220 V
1850 W
app. 25,3 Ohm
Element B
220 V
950 W
app. 49,5 Ohm
Motor
Spray pump motor
220 V/130 W
HI=121 Ohm
HA=30 Ohm
Capacitor
3 ~F
Drain pump motor
220/240 V
30 W
170 Ohm
Timer motor
220/240 V
7880 :t 400 Ohm
Valve
Inlet valve
Double valve
220/240 V
6 W
3620 Ohm
Regeneration valve
220/240 V
8 W
2300 Ohm
Relay
220/240 V
50/60 Hz
5500 Ohm
Thermostats
Indication colour
Thermostat
without
40 °C
SP 40 :t 3 °C RSP 29 :t 5°C
Thermostat
red
55 °C
SP 55 :t 3 °C RSP 40 :t 5°C
Thermostat
white
65 °C
SP 68 :t 3° C RSP 57 :t 5°C
Housing colour
red
Reset safety thermostat
with manual reset
SP 180 :t 7 °C
8.
Water
Levels
Basic level
SP
90 :t 5
RSP 30 :t 5 mm ws
Working level
SP
110:t 5
RSP 41 :t 5 mm ws
High pressure level
SP
2900 + 200
RSP 2400 :t 200 mm ws
Safety level
SP
135 :t 3
RSP 100 :t 5 mm ws
9.
Water Measuring
Water level from fine sieve
Basic level
78 mm
Working level
100 mm
Safety level
136 mm
10. Regenerating
Steps and Volumes
Figure
Volumen
Steps
Water hardness
Figure 2
133 cm3
67-69
10-21° dh = 1,8-3,8 mmol / I
Figure 3
180 cm3
44
22-30° dh = 3,8-5,0 mmol / I
Figure 4
360 cm3
24
31-40° dh = > 5,0 mmol / I