Table 1-3
Table 1-4
NOTE
Introduction
Choosing a Location
Choosing a Location
Physical Specifications
The Fibre Bridge is designed for rackmounting. The unit can be mounted
in most standard 19-inch rack configurations. The physical
characteristics are as follows:
Physical Specifications of the Fibre Bridge
Height
Width
Depth
Physical package
weight
Environmental Specifications
Choose a location that meets the following criteria:
Location Criteria
Room temperature
Humidity
Power source
Clearance
See Chapter 2 for rackmounting instructions.
1-6
1.7 inches (4.2 cm)
16.9 inches (42.9 cm)
9 inches (22.8 cm)
Approximately 8 pounds (3.6 kg)
40–104° F (5–40° C).
5% to 80% relative humidity, non-condensing.
AC power voltage: 100/120V to 220/240 V.
Rackmount configuration—requires 1 EIA
unit in a rack. 1 EIA = 1.75 inches (44 mm).
Requires 5 inches (125 mm) clearance between
the rear edge of the Fibre Bridge and the
backplane of the rack, to allow adequate room
for cables.
Chapter 1