The syntax for setting a special function is
value. To view a function's setting, use
values of the
variable are different for each command/function. These values are given in the
X?
rightmost column.

Command/response table for special function SIS commands

Command
PAL file mode (2:2 pulldown detction)
Set mode on
Set mode off
View file mode status
Blue mode
Set Blue mode on
Set Blue mode off
View Blue mode status
Auto switch
Set Auto switch mode on
Set Auto switch mode off
View Auto switch mode status
H Format (sync output format)
Set to horizontal sync
Set to composite sync
View H Format status
*
# where
X?
X!
# where
is the function number. In the following table the
X?
X?
ASCII Command Response
(host to scaler)
(scaler to host)
18*1#
PDn1
18*0#
PDn0
18#
PDn
X2
8*1#
Blu1
8*0#
Blu0
8 #
Blu
X2
10*1#
Aut1
10*0#
Aut0
10#
Aut
X2
15*1#
HFm0
15*0#
HFm1
15#
HFm
X2
is the function number and
X?
values
X!
and additional descriptions
Set PAL file mode on.
Set PAL file mode off.
Show PAL file mode status.
Set Blue mode on.
Set Blue mode off.
Show Blue mode status.
Set Auto switch mode on.
Set Auto switch mode off.
Show Auto switch mode
status.
Set H format to off/0
(horizontal sync, default).
Set H format to on/1
(composite sync).
Show H format mode status.
IN1502 • Serial Communication
is the
X!
3-7