Failure To Delete Security Key; Failure To Instant Secure Erase Task On Physical Disks; General Issues; Perc Card Has Yellow Bang In Device Manager - Dell PowerEdge H730P User Manual

Raid controller (perc) for dell poweredge r920 systems
Table of Contents

Advertisement

create an unsecured virtual disk even if there is a security key. Select the Secure VD option as No in the
Create New VD menu. For steps on how to create an unsecured virtual disk, see

Failure To Delete Security Key

A security key is used to lock or unlock access to a security-enabled component. This key is not utilized
in the actual encryption of data. If a security key is present, both secured and unsecured virtual disks may
exist.
To delete the security key, you must have a previously established security key present on the controller
and there cannot be any configured secured disks. If there are configured secured disks, remove or
delete them.

Failure To Instant Secure Erase Task On Physical Disks

Instant Secure Erase is the process of securely erasing all data permanently on an encryption-capable
physical disk and resetting the security attributes. It is used in a couple of scenarios such as deleting a
foreign configuration in the event of a forgotten or lost passphrase or unlocking a disk that had been
previously locked.
Instant Secure Erase can be executed only on encryption-capable disks as long as the disks are not hot
spares and are not configured (part of a virtual disk). Ensure that the conditions are met and see
Secure
Erase.

General Issues

PERC Card Has Yellow Bang In Device Manager

Issue:
The device is displayed in Device Manager but has a yellow bang (exclamation
mark).
Corrective
Reinstall the driver. For more information on reinstalling drivers, see
Action:
Installation.

PERC Card Not Seen In Device Manager

Issue:
The device does not appear in the Device Manager.
Corrective
Turn off the system and reseat the controller.
Action:
For more information, see

Physical Disk Issues

Physical Disk In Failed State

Issue:
One of the physical disks in the disk array is in the failed state.
Corrective
Update the PERC cards to the latest firmware available on dell.com/support.
Action:
78
Installing The PERC H730P
Creating A Virtual
Instant
Driver
Card.
Disks.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents