Dell PowerEdge H730P User Manual page 22

Raid controller (perc) for dell poweredge r920 systems
Table of Contents

Advertisement

See the following table for a list of RLM/OCE possibilities.
Table 2. RAID Level Migration
Source RAID
Target RAID
Level
Level
RAID 0
RAID 0
RAID 0
RAID 1
RAID 0
RAID 5
RAID 0
RAID 6
RAID 1
RAID 0
RAID 1
RAID 5
RAID 1
RAID 6
RAID 5
RAID 0
22
Number of
Number of
Physical Disks
Physical Disks
(Beginning)
(End)
1
2 or more
1
2
1 or more
3 or more
1 or more
4 or more
2
2 or more
2
3 or more
2
4 or more
3 or more
3 or more
Capacity
Description
Expansion
Possible
Yes
Increases
capacity by
adding disks.
No
Converts a
non-redundant
virtual disk into
a mirrored
virtual disk by
adding one
disk.
Yes
At least one
disk needs to
be added for
distributed
parity data.
Yes
At least two
disks need to
be added for
dual distributed
parity data.
Yes
Removes
redundancy
while increasing
capacity.
Yes
Maintains
redundancy
while doubling
capacity.
Yes
Two disks
required to be
added for
distributed
parity data.
Yes
Converts to a
non-redundant
virtual disk and
reclaims disk
space used for
distributed
parity data.

Hide quick links: