Maintenance - MULTIQUIP LT6D Operation Manual

Light tower/generator (kohler kdw 1003 diesel engine)
Table of Contents

Advertisement

BasIC InspeCTIOn anD maInTenanCe
See Table 9 below for a general inspection and maintenance checklist. For more detailed maintenance, refer to the engine
service manual.
Frequency
Check Engine Fluid Levels
Check Fuel Filter
Check Air Cleaner Dust Indicator (if equipped)
Check for Leaks/Visual Walk Around
Check for Loosening of Parts
Replace Engine Oil and Filter
Service Battery
Engine
Clean Unit, Inside and Outside
Change Fuel Filter
Clean Radiator and Check Coolant Protection Level
Replace Air Filter Element
Test Thermostats
Check all Hoses and Clamps/Flush Radiator
Clean Inside of Fuel Tank
Generator
Measure Insulation Resistance Over 3M ohms
— Replace engine oil and filter at 100 hours, first time only.
*
— Replace fuel filter at 250 hours, first time only.
**
page 36 — LT6D LIgHT TOWeR • OpeRaTIOn manuaL — Rev. #0 (07/16/13)
Table 9. Inspection/maintenance
*
**

maintenance

10 hrs
200 hrs
500 hrs
Daily
X
X
X
X
X
X
X
X
X
1000
hrs
X
X
X
X
X
X

Advertisement