3Rd Power Supply Fail Signal Enable/Disable; I C To Pci Enable/Disable; Compact Flash Master/Slave; Vga Enable/Disable - Supermicro H8DCR-3 User Manual

Serverboard
Table of Contents

Advertisement

3rd Power Supply Fail Signal
Enable/Disable
The system can notify you in the event
of a power supply failure. This feature
assumes that three redundant power
supply units are installed in the chas-
sis. If you only have one or two power
supplies installed, you should disable
the function with the J3P header to pre-
vent false alarms. See the table on the
right for jumper settings.
2
I
C to PCI Enable/Disable
2
The JI
C1/2 pair of jumpers allows you
to connect the System Management
Bus to any one of the PCI expansion
slots. The default setting is closed (on)
for both jumpers to enable the connec-
tion. Both connectors must be set the
same (JI
2
C1 is for data and JI
the clock). See the table on right for
jumper settings

Compact Flash Master/Slave

The JCF1 jumper allows you to assign
either master or slave status to an
installed compact fl ash card. See the
table on the right for jumper settings.

VGA Enable/Disable

JPG1 allows you to enable or disable
the VGA port. The default position is
on pins 1 and 2 to enable VGA. See
the table on the right for jumper set-
tings.
2
C2 is for
2-17
Chapter 2: Installation
3rd Power Supply Fail Signal
Jumper Settings (J3P)
Jumper Setting
Defi nition
Open
Disabled
Closed
Enabled
I
2
C to PCI Enable/Disable
Jumper Settings
(JI
2
C1/2)
Jumper Setting
Defi nition
Closed
Enabled
Open
Disabled
Compact Flash
Master/Slave
Jumper Settings (JCF1)
Jumper Setting
Defi nition
Closed
Master
Open
Slave
VGA Enable/Disable
Jumper Settings (JPG1)
Jumper Setting
Defi nition
Pins 1-2
Enabled
Pins 2-3
Disabled

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8dcr-i

Table of Contents