To
adjust
grill
burner
air
shutters:
The left hand air shutter controls
the rear
_
_
GRILL BURNER A IRSHUTTER
half of the grill burner. The right hand shutter
_
_
_o9, _
c ont rols the front half.
____c°_o_
i_"
Slide air shutter
backward
or forward
to
A_ROPEN_NG_'_J
increase or decrease the size of the air open-
AIR SHUTTER _
L ,_'_=_
ing. Air shutters fit snugly on the grill burner,
INSERT SCREWDRIVER
BLADE
IN SLOT AND TWIST WITH
so a screwdriver
blade may be required to
SLIGHT PRESSURETOALLOW
make this adjustment.
Observe
change
in
A_R S HUTTER
TO SLIDE E ASILY.
flame appearance as the air shutter is moved.
Adjustment
is satisfactory
when a clearly defined,
even blue flame results
at the
Hi flame setting. The snug fit of the air shutter
assures it will remain
positioned
correctly.
On any burner, closing the air shutter
too far will cause the flame to become soft
and yellow
tipped. Opening
the air shutter
too wide will cause the flame to blow
away from the burner ports. Proper adjustment
will produce a sharp, clearly defined,
even, blue flame.
Lo Flame
Adjustment
This appliance
has been shipped
from the factory
with Lo and Meal flame settings
adjusted
for use with natural gas and average installations.
There is a wide variety
of conditions
caused by altitude and gas mixtures
controlled
by utility companies,
which will vary and affect the gas flame and performance.
Adjustments
should
be
made at time of installation.
If conditions
change,
follow
the procedures
outlined
below to adjust the Lo setting.
To adjust
the
Lo setting:
1. Light burner and set control knob for low flame.
2. Remove control
knob from valve stem.
CAUTION:
Never use a metal blade to pry knob off. If knob cannot
be easily removed,
tuck the folds of a cloth dishtowel
under the knob
skirt and pull the towel
upward with steady, even pressure.
3. Insert a slender, thin-blade
screwdriver
_
COUNTERCLOCKWISE
I._-_*l
TO INCREASE FLAME
into the recess at center of valve stem
_
S_ZE
and engage blade with slot in adjusting
CLOCKWtSE
L li_lll ,.
screw.
TO REDUCE
FLAME SIZE
4. Turn center stem adjusting screw slightly
(__
.,.,
to set flame size. Note: Turn clockwise
to reduce or counterclockwise
to in-
crease flame size.
VALVE
5. Replace control knob when adjustment
STEM
is completed.
Proper adjustment
will produce
a stable, steady
blue flame of minimum
size. The
final adjustment
should
be checked
by turning
knob from Hi to Lo several times
without extinguishing
the flame.
This adjustment,
at the Lo setting, will automatically
provide the proper flame size
at Med setting.