Master-Slave Operation (Sound Active):
you to link up to 16 units together and operate without a controller.
In Master-Slave mode, the units will react to sound. In Master-Slave
operation one unit will act as the controlling unit and the others will
react to the controlling units programs. Any unit can act as a Master
or as a Slave.
1. Using standard XLR microphone cables, daisy chain your units
together via the XLR connector on the rear of the units. Remem-
ber the Male XLR connector is the input and the Female XLR
connector is the output. For longer cable runs we suggest a
terminator at the last fixture.
2. See page 16 for Master/Slave dipswitch positions. Choose a unit
to function as the Master and set the dipswitch accordingly. This
unit must be the first unit in line. Then simply daisy chain the units
together using XLR cables.
3. Now set the Slave units dipswitches accordingly, and they will
react the same as the MASTER.
4. The optional MINI/C Controller (not included) may be used to
control a blackout function.
Built-In Program:
This mode allows a single unit to run a built-in
program. Use this mode when running a single unit, or when running
a Master/Slave configuration.
1. Follow the dipswitch settings on page 16.
2. The unit will run the built-in internal program that you have
chosen.
3. The optional MINI/C Controller (not included) may be used with
this mode to control a blackout function.
American DJ
- www.americandj.com - Emerald Scan™ Instruction Manual Page 13
©
®
Operation
This mode will allow
Emerald Scan™
Channel
Value
1
0 - 255
2
0 - 255
3
0 - 255
4
0 - 255
Emerald Scan™
Fixture Cleaning:
Due to fog residue, smoke, and dust cleaning
the internal and external lenses should be carried out periodically to
optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Clean the external optics with glass cleaner and a soft cloth every
20 days.
3. Always be sure to dry all parts completely before plugging the
unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (I.e. smoke, fog residue, dust, dew). In heavy use we recom-
mend cleaning on a monthly basis. Periodic cleaning will ensure lon-
gevity, and crisp beam output.
Emerald Scan™
This unit is equipped with a built-in safety breaker. This breaker is
designed to close the power circuit in the event of an internal short
or power surge. This will reduce the risk of electrical shock or fire and
protect the circuitry. To reset the breaker, push the breaker button in
until you hear it "pop" back in to place. If the breaker continues to
pop, stop using the unit and contact our customer support team, the
unit may need to be returned for service.
American DJ
- www.americandj.com - Emerald Scan™ Instruction Manual Page 14
©
®
DMX Traits
Function
PAN
TILT
PATTERNS
FOLLOW CHART ON NEXT PAGE
LASER GLITTER
(This increases and decreases the
lazer line size and the gap size in the
patterns)
Breaker Reset
Cleaning

Advertisement

Table of Contents
loading

Table of Contents