Fujitsu SCALEOVIEW S17-2 Operating Manual page 40

Encore, encore s and eclipse series
Table of Contents

Advertisement

Maintaining Units
Recommended
Frequency
Once a week or if
a customer
complaint arises
Once a week or
as notified about
a potential
problem
Page 36
Components
Recommended Maintenance
Hose
1. Inspect hose retrievers for frayed or broken
retrievers
cables.
2. Inspect hose retrievers for cables wrapped
around hoses.
Notes:
1. If repair is required, call an ASC/CSC.
2. When hose retrievers are used, the breakaway
whip hose must be attached to the nozzle, and
the breakaway coupling attached to the whip
hose, with the retriever clamp positioned between
the breakaway coupling and the dispenser outlet
casting. When retrievers are not used, the
breakaway whip hose is attached to the dispenser
outlet casting and the breakaway coupling is
attached to the other end of the breakaway whip
hose.
WARNING
Do not attempt to make these repairs yourself. Doing so could
result in severe injury or death.
Nozzles and
1. Inspect nozzles for the following:
boot area
• Damage
• Leaks
• Loose nozzle spouts
• Missing parts, such as retainer springs and
splash guards
WARNING
If you find a leak, stop using the pump/dispenser, and contact
your local ASC/CSC. Fire, explosion, or electrical shock could
result, if you continue to use a damaged pump/dispenser.
2. Inspect vapor recovery boots (bellows) for proper
seal and signs of damage.
3. Consult the nozzle manufacturer for any
additional required inspections.
Note: If repair is required, call an ASC/CSC.
WARNING
Do not attempt to make these repairs yourself. Doing so could
result in severe injury or death.
MDE-3893P Encore® and Eclipse® Series Owner's Manual · December 2011
Periodic Inspections
Who Performs the
Inspection/Repair
• Owner—Inspect
• ASC/CSC only—Repair
and test
CAUTION
• Owner—Inspect
• ASC/CSC only—Repair
and test
CAUTION
CAUTION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents