Download Print this page

Technical Specifications - HP PROLIANT ML330 Quickspecs

Generation 6
Hide thumbs Also See for PROLIANT ML330:

Advertisement

QuickSpecs

Technical Specifications

System Unit
Tower Dimensions
(H x W x D)
(W/O foot stand)
Tower Weight
(approximate)
Input Requirements
(per power supply)
BTU Rating
Power Specifications
Power Supply Output
(per power supply)
System Inlet
Temperature
Relative Humidity
(non-condensing)
DA - 13361 Worldwide QuickSpecs — Version 17 — 3-31-2010
7.87 x 16.81 x 24.13 in (200 x 427 x 613 mm)
Maximum:
(All hard drives, power
supplies and processors
installed)
Minimum:
(One hard drive, power
supply and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Calculator which
is available via the online tool located at URL:
energy-efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: ML330 G6
- Follow the instructions of the next screens.
Rated Steady-State
Power
Maximum Peak Power
Operating
Non-Operating
Operating
Non-operating**
HP ProLiant ML330 Generation 6
30 kg
16 Kg
100 to 240 VAC
7.1 Amps (at 120VAC) to 3.5 Amps (at 240
VAC)
50 to 60 Hz
852 W
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at
240 VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600
(at 240 VAC)
www.hp.com/go/proliant-
460 (750) W (at 100 VAC),
460 (750) W (at 200 VAC)
460 (750) W (at 100 VAC),
460 (750) W (at 200 VAC)
NOTE: See Power Supply Specifications
tables for complete details on 460W PSU and
optional 750W.
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per 1,000 ft (1.0° C
per every 305 m) above seal level to a
maximum of 10,000 ft (3050 m) no direct
sustained sunlight . Maximum rate of change
is 18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be
reduced if operating with a fan fault or above
86°F (30°C).
-22° to 140° F (-30° to 60° C)
10% to 90% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature,
non-condensing.
Page 41

Advertisement

loading

This manual is also suitable for:

Proliant ml330 g6