Millivolt Appliance Checkout; Electronic Appliance Checkout - Lennox MPB3328CNM-B Care And Operation Instructions Manual

Merit plus series mpb b-vent gas fireplaces
Hide thumbs Also See for MPB3328CNM-B:
Table of Contents

Advertisement

burner Air Shutter Adjustment Procedure
WARNINGS
• Air shutter adjustment should
only be performed by a quali-
fied professional service
technician.
• Ensure front glass panel are
in place and sealed during
adjustment.
CAUTIONS
Soot
will be produced if the
air shutter is closed too much.
Any damage due to carboning
resulting from improperly
setting the air shutter is not
covered under the warranty.
• The air shutter door and nearby
appliance surfaces are hot.
Exercise caution to avoid
injury while adjusting flame
appearance.
burner Adjustments
Note - The air shutter for the burner primary
air opening is factory-set. Do not adjust the
factory-set position. The factory-set position
is shown in Figure 16.
18
Main burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model
Natural
Gas
MPb-3328
Fully Closed
MPb-3530
Fully Closed
MPb-4035
Fully Closed
MPb-4540
Fully Closed
Figure 16
SIT Millivolt Appliance Checkout
The pilot flame should be steady, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" min (tip) of the
quick drop out thermocouple should be engulfed
in the pilot flame. The flame should project 1"
(25 mm) beyond the hood at all three ports
(Figure 17).
To light the burner, refer to the lighting instruc-
tions on Pages 24 and 25.
SIT MILLIVOLT PILOT ASSEMbLY
Proper Pilot Flame Appearance
Igniter Rod
Hood
Thermocouple
Pilot
Nozzels
Thermopile
Figure 17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
burner Air Shutter Adjustment
Setscrew - Factory located in the natural gas
Propane
position; relocate set screw for LP/propane
Gas
gas in the alternate position. See table for air
shutter openings for these setscrew locations.
3/16"
(4.76 mm)
3/16"
(4.76 mm)
Venturi
3/16"
(4.76 mm)
Air Shutter
3/16"
(4.76 mm)
Ref. Air shutter Patent:
U.S. Pat. 5,553,603

Electronic Appliance Checkout

To light the burner, refer to the lighting instruc-
tions on Pages 26 and 27. Ensure the igniter
lights the pilot. The pilot flame should engulf
the flame sensor as shown in Figure 18.
ELECTRONIC PILOT ASSEMbLY
Proper Pilot Flame Appearance
Proper Flame
Adjustment
Pilot
Nozzels
3/8" Min.
Figure 18
(9 mm)
3/8" to 1/2"
(9 -13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Igniter