LENNOX CRESTLINE™ SERIES B-VENT GAS FIREPLACES • 36"/42" LSBV MODELS • CARE AND OPERATION INSTRUCTIONS
Millivolt appliances may be fitted at time of
manufacture with either a Honeywell millivolt
gas control valve or as SIT millivolt gas control
valve. Both valves have been tested with and
approved for use with these appliances and are
listed accordingly.
Test gage connections are provided on the front
of the millivolt gas control valves (identified OUT
for the manifold side and IN for inlet pressure
side for both SIT and Honeywell equipped
appliances.
Minimum inlet gas pressure to the appliance is
5.0 inches water column (9.5 MmHg) for natural
gas and 11 inches water column (20.55 MmHg)
for propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to the
appliance is 10.5 inches water column (19.95
MmHg) for natural gas and 13.0 inches water
column (24.25 MmHg) for propane.
The appliance must be isolated from the gas
supply piping system (by closing its individual
manual shut-off valve) during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.5 kPa).
The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of 1/2 psig
(3.5 kPa).
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
WARNING: FAILURE TO COMPLy WITH
THE INSTALLATION AND OPERATING
INSTRUCTIONS PROVIDED IN THIS
DOCUMENT WILL RESULT IN AN IM-
PROPERLy INSTALLED AND OPERATING
APPLIANCE, VOIDING ITS WARRANTy.
ANy CHANGE TO THIS APPLIANCE AND/
OR ITS OPERATING CONTROLS IS DAN-
GEROUS. IMPROPER INSTALLATION OR
USE OF THIS APPLIANCE CAN CAUSE
SERIOUS INjURy OR DEATH FORM
FIRE, BURNS, ExPLOSION OR CARBON
MONOxIDE POISONING.
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning are similar
to the flu with headaches, dizziness and/
or nausea. If you have these signs, obtain
fresh air immediately. Turn off the gas sup-
ply to the appliance and have it serviced by
a qualified professional, as it may not be
operating correctly.
WARNING: B-VENT APPLIANCES ARE
NOT DESIGNED TO OPERATE IN NEGA-
TIVELy PRESSURED ENVIRONMENTS
(PRESSURE WITHIN THE HOME IS
LESS THAN PRESSURES OUTSIDE).
SIGNIFICANT NEGATIVELy PRESSURED
ENVIRONMENTS CAUSED By WEATHER,
HOME DESIGN, OR OTHER DEVICES MAy
IMPACT THE OPERATION OF THESE AP-
PLIANCES. NEGATIVE PRESSURES MAy
RESULT IN POOR FLAME APPEARANCE,
SOOTING, DAMAGE TO PROPERTy AND/
OR SEVERE PERSONAL INjURy. DO NOT
OPERATE THESE APPLIANCES IN NEGA-
TIVELy PRESSURED ENVIRONMENTS.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAzARDS
OF HIGH SURFACE TEMPERATURES. USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
yOUNG CHILDREN SHOULD BE CARE-
FULLy SUPERVISED WHEN THEy ARE
IN THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING
OR OTHER FLAMMABLE MATERIALS ON
OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VêTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIqUIDES à VAPEUR INFLAMMABLES
LIN DE L'APPAREIL.
OPERATION AND CARE OF yOUR
APPLIANCE
1. Appliance operation may be controlled
through a remotely located wall switch (nt
supplied) or optional remote control kit. In lieu
of remote wall switch operation, the appliance
must be operated directly through the controls
located on the front of the valve located within
the control compartment under the removable
refractory access panel, Figure 1.
Operation of millivolt and electronic gas control
systems are different. Before lighting and op-
erating your appliance determine if you have a
millivolt or electronic appliance. Refer to Figure
1 to access the gas control compartment below
the lower refractory panel.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
SIT Valve
Shown
Refractory
Access Panel
Figure 1
Millivolt appliances will be fitted with the gas
control valve shown in Figure 2 on page 4.
Appliances with electronic systems will be fitted
with the electronic valve shown in Figure 3 on
page 4. Familiarize yourself with the differing
controls for the valve your appliance uses.
To light millivolt appliances refer to the detailed
lighting instructions found in both English and
French on pages 12 and 13 of these instructions
respectively. Millivolt and electronic appliance
lighting instructions may also be found on the
pull out rating plate located within the gas
control compartment. Refer to Figure 2 for the
spark ignitor location used with your appliance.
If your millivolt appliance is equipped with an
optional remote wall switch or remote control
kit the appliance main burner may be turned on
and off with the wall switch or remote control.
If the appliance is not equipped with a wall or
remote control, the main burner must be turned
off and on with the gas control knob. Turn the
knob counter-clockwise from the PILOT position
to ON to light the main burner, and clockwise
from ON to PILOT to turn off the main burner.
To light electronic appliances refer to the
detailed lighting instructions found in both
English and French on pages 14 and 15 of
these instructions respectively. Millivolt and
electronic appliance lighting instructions
may also be found on the pull out rating plate
located within the gas control compartment.
If your electronic appliance is equipped with an
optional remote wall switch or remote control kit
the appliance main burner may be turner on and
off with the wall switch or remote control. If the
appliance is not equipped with a wall switch or
remote control, the main burner must be turned
off and on with the gas control switch. Toggle
the switch from ON to OFF to operate the main
burner from ON to OFF.