Specifications; City Code Table - Casio 5242 Operation Manual

Table of Contents

Advertisement

Specifi cations
Accuracy at normal temperature: ± 15 seconds a month (with no signal calibration)
Timekeeping: Hour, minutes (hand moves every 10 seconds), seconds, day, day of the week
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Other: Home City code (can be assigned one of 29 city codes and Coordinated Universal Time);
Daylight Saving Time (summer time) / Standard Time
Time Calibration Signal Reception: Auto receive up to six times a day (5 times a day for the Chinese
calibration signal; Remaining auto receives cancelled as soon as one is successful); Manual
receive
Receivable Time Calibration Signals:
Mainfl ingen, Germany (Call Sign: DCF77, Frequency: 77.5 kHz); Anthorn, England (Call Sign:
MSF, Frequency: 60.0 kHz); Fukushima, Japan (Call Sign: JJY, Frequency: 40.0 kHz); Fukuoka/
Saga, Japan (Call Sign: JJY, Frequency: 60.0 kHz); Fort Collins, Colorado, the United States
(Call Sign: WWVB, Frequency: 60.0 kHz); Shangqiu City, Henan Province, China (Call Sign:
BPC, Frequency: 68.5 kHz)
Compass: 20 seconds continuous reading; North indication by hand; Calibration (bidirectional, northerly);
Manual reading
Altimeter:
Measurement range: –700 to 10,000 m (or –2,280 to 32,800 ft.) without reference altitude
Display range: –3,000 to 10,000m (or –9,840 to 32,800 ft.)
Negative values can be caused by readings produced based on a reference altitude or due to
atmospheric conditions.
Measurement unit: 10 m (or 40 ft.)
Other: Calibration; Manual reading
E-80
Pressure Sensor Precision:
Conditions (Altitude)
± (altitude differential × 2%
0 to 6000 m
+ 15 m) m
0 to 19680 ft.
± (altitude differential × 2%
+ 50 ft.) ft.
Fixed
temperature
± (altitude differential × 2%
6000 to 10000 m
+ 25 m) m
19680 to 32800 ft.
± (altitude differential × 2%
+ 90 ft.) ft.
0 to 6000 m
± 50 m every 10°C
Effect of
0 to 19680 ft.
± 170 ft. every 50°F
variable
6000 to 10000 m
± 70 m every 10°C
temperature
19680 to 32800 ft.
± 230 ft. every 50°F
Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
Precision is lessened by strong impact to either the watch or the sensor, and by temperature extremes.
Temperature Sensor Precision:
±2°C (±3.6°F) in range of –10°C to 60°C (14°F to 140°F)
Alarm: Daily alarm
Stopwatch:
Measuring unit: 1 second
Measuring capacity: 11:59' 59"
Measuring modes: Elapsed time
E-82

City Code Table

City Code
PPG
(PAGO PAGO)
HNL
(HONOLULU)
ANC
(ANCHORAGE)
LAX
(LOS ANGELES)
DEN
(DENVER)
CHI
(CHICAGO)
NYC
(NEW YORK)
SCL
(SANTIAGO)
RIO
RAI
(PRAIA)
UTC
LON
(LONDON)
PAR
(PARIS)
ATH
(ATHENS)
JED
(JEDDAH)
THR
(TEHRAN)
DXB
(DUBAI)
KBL
(KABUL)
KHI
(KARACHI)
DEL
(DELHI)
L-2
Operation Guide 5242
Altimeter
Barometer
± (pressure differential × 2%
+ 2 hPa) hPa
± (pressure differential × 2%
+ 0.059 inHg) inHg
± 5 hPa every 10°C
± 0.148 inHg every 50°F
UTC Offset/
City
GMT Differential
Pago Pago
–11
Honolulu
–10
Anchorage
–9
Los Angeles
–8
Denver
–7
Chicago
–6
New York
–5
Santiago
–4
Rio De Janeiro
–3
Praia
–1
0
London
Paris
+1
Athens
+2
Jeddah
+3
Tehran
+3.5
Dubai
+4
Kabul
+4.5
Karachi
+5
Delhi
+5.5
Barometer:
Measurement range: 260 to 1,100 hPa (or 7.7 to 32.5 inHg)
Display unit: 1 hPa (or 0.1 inHg)
Other: Calibration; Manual reading; Barometric pressure differential indicator
Thermometer:
Measurement range: –10.0 to 60°C (or 14 to 140°F)
Measurement unit: 0.1°C (or 1°F)
Other: Calibration; Manual reading
Bearing Sensor Precision:
Direction: Within ±12°
Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
Illumination: LED (light-emitting diode); Selectable illumination duration; Auto Light Switch (Full Auto LED
Light operates only in the dark)
Other: Power Saving function; Low battery alert (second hand jumping at 2-second intervals); Auto hand
position adjustment
Power Supply: Solar panel and one rechargeable battery
Approximate battery operating time: 7 months (from full charge to Level 3) under the following
conditions:
Alarm: 10 seconds/day
Light: 1.5 seconds (one operation)/day
Second hand operation: 18 hours/day
Time calibration receive: 4 minutes/day
Direction reading: 20 times/month (20 seconds continuous reading)
Readings using the barometric pressure differential indicator: 12 times/day
Climbs: Once (30 altituded readings)/month
Frequent use of illumination runs down the battery. Particular care is required when using the auto
light switch (page E-71).
City Code
KTM
(KATHMANDU)
DAC
(DHAKA)
RGN
(YANGON)
BKK
(BANGKOK)
HKG
(HONG KONG)
TYO
(TOKYO)
ADL
(ADELAIDE)
SYD
(SYDNEY)
NOU
(NOUMEA)
WLG
(WELLINGTON)
Based on data as of December 2010.
The rules governing global times (UTC offset and GMT differential) and summer time are determined
by each individual country.
UTC Offset/
City
GMT Differential
Kathmandu
+5.75
Dhaka
+6
Yangon
+6.5
Bangkok
+7
Hong Kong
+8
Tokyo
+9
Adelaide
+9.5
Sydney
+10
Noumea
+11
Wellington
+12
E-81
E-83
L-1
L-3

Advertisement

Table of Contents
loading

Table of Contents