Configuration
3.6.6

RS232/RS485 Setup Screen

42
Siemens Building Technologies
Fire & Security Products
The RS232/RS485 setup screen allows you to set up the RS232 and RS485 ports
to communicate with external devices such as modems, remote controls and dome
cameras.
Fig. 43
RS232/RS485 setup screen.
Highlight the field for the settings you wish to make. Select the correct Baud Rate,
Parity, Data Bits and Stop Bits for the device you are connecting to the DVR.
For RS485, it is possible to select either Remote Control or PTZ Control in the
Usage field.
It is possible to select either External Modem or Remote Control in the RS232 ─
Usage field, and select either Remote Control or PTZ Control in the RS485 ─
Usage field.
NOTE:
Both the RS232 and RS485 ports cannot be configured to communicate with remote controls at the
same time.
NOTE:
If networking is configured by the external modem, the RS232 port cannot be set up for the remote
control. In the Network Setup menu, set up the DVR for LAN connections first.