Vent Clearances And Framing; Pipe Clearances To Combustibles - Heat & Glo 8000TR-OAK Owner's Manual

Direct vent gas appliance heater
Hide thumbs Also See for 8000TR-OAK:
Table of Contents

Advertisement

6 6

Vent Clearances and Framing

A. Pipe Clearances to Combustibles
WARNING
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as
specifi ed.
• Do not pack air space with insulation or
other materials.
Failure to keep insulation or other materials
away from vent pipe may cause fi re.
Note: Slope
not required.
1 in. CLEARANCE
AROUND VERTICAL
SECTIONS
Figure 6.1 Pipe Clearances
Heat Shield Above First 90
WARNING
Fire Risk.
Installation of this fi replace may require the use
of heat shield 385-290 above the fi rst 90
in the venting system.
• Heat shield required if vertical distance between top of
horizontal elbow and any combustible surface above
elbow is less than 4 inches.
• Heat shield not required if distance is more than 4
inches.
Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev. o • 9/08
3 in. TOP
CLEARANCE
1 in. SIDE AND
BOTTOM CLEARANCE
0
Elbow
0
elbow
COMBUSTIBLE
SURFACE
HEAT
SHIELD
Figure 6.2
Fasten the shield in place using the four pilot holes pro-
vided in the part.
• Position the shield so the longest dimension (13-1/2 in.)
is placed in same direction the elbow is pointing.
• Center the shield directly above the elbow with a 1/2 inch
air space between shield and combustible surface (see
Figure 6.3).
COMBUSTIBLE SURFACE
CORRECT
DIRECTION
HEAT SHIELD
90º ELBOW
Figure 6.3
3" MIN.
(76mm)
INCORRECT
UP
21

Hide quick links: