2) Remove all ice from the storage bin.
3) Plug the unit back in.
4) Slowly pour 16 to 24 oz. (500 to 750 ml) of water over the storage bin drain hole in the
storage bin.
5) If water pumps out properly and the drain pump then de-energizes, proceed to step 6. If
water does not pump out properly and/or the drain pump does not de-energize, follow
the steps below to prime the drain pump.
Priming Instructions
a. Disconnect the icemaker's power cord from the electrical outlet, then reconnect
to the electrical outlet. WARNING! To reduce the risk of electric shock, do not
touch the power cord with damp hands.
b. Slowly pour another 16 to 24 oz. (500 to 750 ml) of water over the storage bin drain
hole in the storage bin. If not already energized, the drain pump should energize.
c. Confirm that water is discharged through the discharge hose. The drain pump
should then de-energize. If not, repeat steps a through c until water is discharged
through the discharge hose and the drain pump de-energizes. The drain pump is
primed when the drain pump de-energizes.
d. If water now pumps out properly and the drain pump de-energizes, proceed to
step 6. If water still does not pump out properly and/or the drain pump does not
de-energize, the unit must be serviced by a qualified service technician before
proceeding.
6) Move the power switch to the "ON" position.
7) Pour another 16 to 24 oz. (500 to 750 ml) of water into the icemaker's ice storage bin,
then completely restrict the discharge hose while the drain pump is operating. See
Fig. 35. Pour more water into the icemaker's ice storage bin until the icemaker turns off.
The drain pump will continue to operate. Check for leaks.
8) Remove the discharge hose restriction and allow the water to be pumped out normally.
Power to the icemaker will be restored when the water in the drain pump returns to a
normal level.
9) If the icemaker fails to turn off with the discharge hose restricted or the pump fails to
pump out the water, the unit must be serviced by a qualified service technician.
Fig. 35
37
Discharge Hose