3Com Router 5000 and Router 6000 v2.41
Module Guide
1
2
3
4
5
6
7
8
Figure 2-14 Default setting of the DIP switches
8BIT description and settings of DIP switch are given in the following table:
Table 2-10 Description and settings of the internal DIP switch of SIC-ERRI/Router 1-Port Fractional E1
SIC
DIP switch
1BIT
2BIT
3BIT
4BIT
5BIT
6BIT
7BIT
on
Description
Switch for
75-ohm/120-ohm
options
Switch for RxRing
grounding mode options
Switch for RxShield
grounding options
2-15
Chapter 2 Smart Interface Cards
75 -ohm
impedance
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF: RxRing
grounding via
capacitor
-
ON: RxRing directly
grounding
ON: RxShield grounding
-
OFF: RxShield
ungrounding
120 -ohm impedance