Table 1. Features and specifications (continued)
Simple-swap fans:
v Two (one microprocessor installed)
v Three (two microprocessors installed)
v Three additional fans (for optional
redundant cooling)
Size:
v Tower
– Height: 440 mm (17.3 in.)
– Depth: 750 mm (29.5 in.)
– Width: 218 mm (8.6 in.)
– Weight: approximately 39.8 kg (87.7
lb) when fully configured or 25.0 kg
(55.1 lb) minimum
v Rack
– 5 U
– Height: 218 mm (8.6 in.)
– Depth: 702 mm (27.6 in.)
– Width: 424 mm (16.7 in.)
– Weight: approximately 39.3 kg (86.6
lb) when fully configured or 24.5 kg
(54.0 lb) minimum
Racks are marked in vertical increments of
4.45 cm (1.75 inches). Each increment is
referred to as a unit, or "U." A 1-U-high
device is 4.45 cm (1.75 inches) tall.
Integrated functions:
v Integrated Management Module II
(IMM2), which consolidates multiple
management functions in a single chip.
v Intel I350AM4 Quad Port Gigabit
Ethernet controller with Wake on LAN
support
v Serial over LAN (SOL) and serial
redirection over Telnet or Secure Shell
(SSH)
v One systems-management 1 Gb
Ethernet port for connection to a
dedicated systems-management
network. This system management
connector is dedicated to the IMM2
functions.
v Light path diagnostics
v Six Universal Serial Bus (USB) ports
standard
– Two on front of server
– Four on rear of server
v One internal USB port for optional USB
flash device with embedded hypervisor
v One internal USB tape connector
v One serial connector
RAID controllers (depending on the
model):
v A ServeRAID M1115 SAS/SATA
adapter that provides RAID 0, 1, and
10 with optional FoD RAID 5/50 and
SED (Self Encrypting Drive) upgrade.
v A ServeRAID M5110 SAS/SATA
adapter that provides RAID 0, 1, and
10.
Optional upgrade:
– RAID 5/50 (512 MB Cache) with
optional FoD RAID 6/60 and SED
upgrade
– RAID 5/50 (512 MB Flash) with
optional FoD RAID 6/60 and SED
upgrade
– RAID 5/50 (1 GB Flash) with
optional FoD RAID 6/60 and SED
upgrade
– RAID 5/50 and SED (Zero Cache)
Acoustical noise emissions:
v Sound power, idling: 6.0 bels
v Sound power, operating: 6.0 bels
Environment:
v Air temperature:
– Server on: 10°C to 35°C (50.0°F to
95.0°F); altitude: 0 to 914.4 m
(3000 ft)
– Server on: 10°C to 32°C (50.0°F to
89.6°F); altitude: 914.4 m (3000 ft)
to 2133.6 m (7000 ft)
– Server off (with standby power):
10°C to 43°C (50.0°F to 109.4°F);
maximum altitude: 2133.6 m (7000
ft)
– Shipment: -40°C to 60°C (-40°F to
140°F)
v Humidity:
– Server on: 8% to 80%; maximum
dew point 21°C; maximum rate of
change: 5°C/hour
– Server off (with standby power): 8%
to 80%; maximum dew point: 27°C
v Particulate contamination:
Attention:
Airborne particulates and
reactive gases acting alone or in
combination with other environmental
factors such as humidity or
temperature might pose a risk to the
server. For information about the limits
for particulates and gases, see
"Particulate contamination" on page
139.
Heat output:
Approximate heat output:
v Minimum configuration: 2013 Btu per
hour (590 watts)
v Maximum configuration: 3610 Btu per
hour (1058 watts)
Electrical input:
v Sine-wave input (50 - 60 Hz) required
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA),
approximately:
– Minimum: 0.60 kVA
– Maximum: 1.10 kVA
Notes:
1. Power consumption and heat output
vary depending on the number and type
of optional features installed and the
power-management optional features in
use.
2. The noise emission level stated is the
declared (upper limit) sound power
level, in bels, for a random sample of
machines. All measurements are made
in accordance with ISO 7779 and
reported in conformance with ISO 9296.
Chapter 1. The System x3500 M4 server