7
70(96)
7.4.7.1

Copy parameters

The Copy parameters submenu (S6.3) is located under the System menu.
The Honeywell NX frequency converter features a possibility for the user to store and load two
customised parameter sets (all parameters included in the application, not the system menu
parameters) and to load back the factory default parameter values.
Parameter sets (S6.3.1)
On Parameter sets page (S6.3.1), push the Menu button right to enter the Edit menu. You can store
or load two customised parameter sets or load back the factory defaults. Confirm with the Enter
button. Wait, until 8 (=OK) appears on the display.
Figure 7-10. Storing and loading of parameter sets
7.4.7.2

Security

The Security submenu (S6.5) under the system menu has a function that allows the user to prohibit
changes to the parameters.
Parameter lock (P6.5.2)
If the parameter lock is activated the parameter values cannot be edited.
NOTE: This function does not prevent unauthorised editing of parameter values.
Enter the edit mode by pushing the Menu button right. Use the Browser buttons to change the
parameter lock status (0 = changes enabled, 1 = changes disabled). Accept the change with the
Enter button or return to the previous level with the Menu button left.