Download Print this page

Vulcan-Hart V-24S SERIES Specifications page 2

24" wide heavy duty gas range with open cabinet base

Advertisement

IMPORTANT
1. A properly sized gas pressure regulator suitable for battery or
single unit application must be furnished and installed.
Natural gas 5.0" W.C., propane gas 10.0" W.C.
2. An adequate ventilation system is required for commercial
cooking equipment. Information may be obtained by writing to
the National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269. When writing refer to NFPA No. 96.
3. These units are manufactured for installation in accordance
with ANSZ223.1a (latest edition), National Fuel Gas Code.
Copies may be obtained from the American Gas Association,
1515 Wilson Blvd., Arlington, VA 22209.
MODEL
BTU/HR.
NO.
V4-24S
120,000
V1G-24S
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
F-32496 (10-03)
INPUT
WIDTH
24"
60,000
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
V-24S SERIES
24" WIDE HEAVY DUTY GAS RANGE WITH OPEN
CABINET BASE
4. Clearances:
Combustible
Rear
Sides
5. For proper combustion, install equipment on adjustable legs
or casters. On curb or platform, allow 3
Leveling bolts are required for curb installation. Specify when
ordering.
6. Cannot be batteried with GH series equipment.
7. This appliance is manufactured for commercial installation
only and is not intended for home use.
DEPTH
ON 6" LEGS
38"
Non-Combustible
2"
0"
20"
2"
1
/
" front overhang.
2
WORKING
APPROX.
HEIGHT
SHP. WT.
(lbs./kg)
295/133
36"
360/162
Printed On Recycled Paper