A Board Adjustments - Sony TRINITRON KV-20M42 Service Manual

Sony trinitron color tv service manual
Hide thumbs Also See for TRINITRON KV-20M42:
Table of Contents

Advertisement

KV-20M42/20S42/20S43/21MB42C/21MB42M/21MB42P/21ME42/21ME42C/
21SB42C/21SB42M/21SE42/21SE42C/21SE82/21SE82C

5-4. A BOARD ADJUSTMENTS

H. Frequency Adjustment
1. Input a monoscope signal.
2. Set to Service Adjustment Mode.
3. Connect a frequency counter to base of Q501
(TP-500 H. DRIVE).
4. Select the item of AFC, set to 3 level (free run).
5. Check H. Frequency for the 15735 ± 200 Hz.
6. Select the AFC item again and adjust level to 0.
7. Press
then
V. Frequency Adustment
1. Select video 1 with no signal input.
2. Set the conditions for a standard setting.
3. Connect the frequency counter across TP-508 or CN501
VDY (+) pin
connector and ground.
4. Check that V. Frequency shows 60 ± 2 Hz.
Sub Contrast Adjustment (RDRV)
1. Input a color-bar signal.
2. Set the red color.
3. Set to Service Adjustment Mode.
4. Select the item DCOL level to 0.
5. Set the conditions as follows:
PICTURE:
MAX
COLOR:
MIN
BRIGHT:
CENTER
R ON:
ON (1)
G ON:
OFF (0)
B ON:
OFF (0)
SERVICE
6. Connect an oscilloscope probe to CN301 pin
(R OUT) and ground.
7. Select RDRV with
8. Adjust with
and
9. Reset the item DCOL to 1.
10. Press
then
to save into the memory.
RON
1
1: ON
0: OFF
and
.
for 1.70 ± 0.05 Vp-p
White
1.70 ± 0.05 Vp-p
Black
to save into the memory.
11. Return the following back to normal after adjustment.
PICTURE:
COLOR:
BRIGHT:
R ON:
G ON:
B ON:
Display Position Adjustment (DISP)
1. Input a color-bar signal.
2. Set to Service Adjustment Mode.
3. Select DISP with
4. Adjust with
and
5. Press
then
6. Check to see if the text is displayed on the screen.
SERVICE
Sub Bright Adjustment (SBRT)
1. Input a crosshatch signal.
2. Set to Service Adjustment Mode.
3. Set the PICTURE and BRIGHTNESS to minimum.
4. Select the SBRT item with
5. Adjust with
and
6. Press
then
Sub Hue, Sub Color Adjustment (SHUE, SCOL)
1. Input a color-bar signal.
2. Set to Service Adjustment Mode.
3. Select the DCOL item and set the value to 0.
4. Connect an oscilloscope probe to CN301 Pin
(BLUE OUT) and ground.
5. Select SHUE and SCOL with
6. Adjust with
and
(SCOL) and V2 = V3 ± 0.2 Vp-p (SHUE).
7. Reset the DCOL level to 1.
8. Press
then
— 22 —
MAX
CENTER
CENTER
ON (1)
OFF (0)
OFF (0)
and
.
to adjust characters to the center.
to save into the memory.
DISP
15
and
.
to obtain a faintly visible crosshatch.
to save into the memory.
and
.
for the V1 = V4 ± 0.2 Vp-p
V1
V4
V2 V3
to save into the memory.

Advertisement

Table of Contents
loading

Table of Contents