Sony TRINITRON KV-20M42 Service Manual page 5

Sony trinitron color tv service manual
Hide thumbs Also See for TRINITRON KV-20M42:
Table of Contents

Advertisement

Display of Standby/Timer LED Flash Count
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
Diagnostic Item
+B overcurrent
Vertical deflection stopped
White balance failure
*One flash count is not used for self-diagnostic.
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LED from
flashing.
Self-Diagnostic Screen Display
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confirmed, it is
possible to bring up past occurrences of failure on the screen for confirmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
Channel 5
Display
Self Diagnostic Screen Display
SELF DIAGNOSTIC
2:
0
3:
N/A
0
4:
0
5:
1
101:
N/A
0
KV-20M42/20S42/20S43/21MB42C/21MB42M/21MB42P/21ME42/21ME42C/
LED OFF
3 sec.
Flash Count*
2 times
4 times
5 times
Sound volume
Power ON
Note that this differs from entering the service mode (sound volume
Numeral "0" means that no fault was detected.
Numeral "1" means a fault was detected one time only.
— 5 —
21SB42C/21SB42M/21SE42/21SE42C/21SE82/21SE82C
STANDBY/TIMER LED
+
).