FocusPRO
TH6110D Programmable Thermostat
In case of difficulty
Heating equip-
ment is running
in cool mode
Cannot change
system setting
to "Heat"
Cannot change
system setting
to "Cool"
"Heat On" is
not displayed
"Cool On" is not
displayed
"Cool On" or
"Heat On"
is flashing
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Battery holder ......................................................Part Number 50007072-001
Cover plate assembly ........................................Part Number 50002883-001
(Use to cover marks left by old thermostats.)

Specifications

Temperature Ranges
• Heat: 40° to 90°F (4.5° to 32°C)
• Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
• 32° to 120°F (0° to 48.9°C)
Shipping Temperature
• -20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Physical Dimensions
• 3-9/16" H x 5-13/16" W x 1-1/2" D
• 91 mm H x 147 mm W x 38 mm D
• Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating/cooling equipment (see page 8).
• Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating equipment (see page 8).
• Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Changeover (see page 8).
• Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed cooling equipment (see page 8).
• Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Changeover (see page 8).
• Change the System Setting to Heat, and set the temperature level above
the current room temperature.
• Change the System Setting to Cool, and set the temperature level below
the current room temperature.
• Compressor protection timeout is engaged. Wait 5 minutes for the
system to restart safely, without damage to the compressor.
Electrical Ratings
Terminal
Voltage (50/60Hz)
W (O/B) Heating
(Powerpile)
Y Cooling
G Fan
13
Running Current
20-30 Vac
750 mV DC
20-30 Vac
20-30 Vac
0.02-1.0 A
100 mA DC
0.02-1.0 A
0.02-0.5 A